Stackable Crescent Cuber Models KM-1301SAH/3
KM-1301SWH/3 KM-1301SRH/3 SERVICE MANUAL
HoshizakiHoshizaki America, Inc
•Complete and detailed explanation of the problem
HOSHIZAKI AMERICA, INC 618 Highway 74 South
Peachtree City, GA
Attn: Hoshizaki Technical Support Department
CONTENTS
e Harvest Pump Timer S4 dip switch
f Factory Use S4 dip switch
g Freeze Timer S4 dip switch 9 &
h Float Switch Control S5 dip switch
V. Removal and Replacement of Components
A. Service for Refrigerant Lines
1. Refrigerant Recovery
B. Removal and Replacement of Compressor
Important Safety Information
I. Specifications A. Icemaker
1. KM-1301SAH air-cooled
2. KM-1301SAH3 air-cooled
3. KM-1301SWH water-cooled
4. KM-1301SWH3 water-cooled
5. KM-1301SRHremote air-cooled
6. KM-1301SRH3remote air-cooled
1. URC-14F
B. Condenser Unit
Unit: inches mm
SPECIFICATIONS
MODEL URC-14F
II. General Information A.Construction
1. KM-1301SAH, KM-1301SAH3 air-cooled
2. KM-1301SWH, KM-1301SWH3 water-cooled
3. KM-1301SRH, KM-1301SRH3remote air-cooled
B. Sequence of Operation
1. Sequence Cycles and Shutdown
a1-MinuteFill Cycle
bInitial Harvest Cycle
eHarvest Cycle
dPump-OutCycle
fShutdown
G Control Board Sequence Flow Chart
Timer
KM-1301SAH/3, KM-1301SWH/3,and KM-1301SRH/3
Harvest Pump
C. Control Board
G Control Board
1. Control Board Layout
Control Board
Part Number 2A3792-01
bHarvest Backup Timer and Freeze Timer
cHigh Temperature Safety
dLow Water Safety
aMaximum Water Supply Period - 6 minutes
f LED Lights and Audible Alarm Safeties
aDefault Dip Switch Settings
3. Controls and Adjustments
bHarvest Timer S4 dip switch
c Pump-OutTimer S4 dip switch 3 &
dPump-OutFrequency Control S4 dip switch 5 &
f Factory Use S4 dip switch
e Harvest Pump Timer S4 dip switch
g Freeze Timer S4 dip switch 9 &
h Float Switch Control S5 dip switch
i Refill Counter S5 dip switch 2 through
E. Float Switch
G. Control Switch
D. Bin Control
F. Thermistor
A. Water Circuit and Refrigeration Circuit
III. Technical Information
Tank
KM-1301SWH, KM-1301SWH3 water-cooled
Water Tank
Spray Tubes
Water Tank
B. Wiring Diagrams
1.Auxiliary Code T-0, U-0
a KM-1301SAH air-cooled
Transformer Output 10.5V at
1301SWH water-cooled
Auxiliary Code T-0, U-0bKM
Transformer Output 10.5V at
Auxiliary Code T-0, U-0cKM
Cut-out
412±21
PSIG
water
KM-1301SAH3 air-cooledand KM
1301SWH3
cooled
Auxiliary Code T-0, U-0
KM-1301SRH3remote air-cooled
Transformer Output
10.5V at
Code U-1and Later
Auxiliary
Transformer Output
10.5V at
Auxiliary Code
U-1and Later
b KM-1301SWH water-cooled
10.5V at
Auxiliary Code U-1and Later
c KM-1301SRHremote air-cooled
10.5V at
Transformer Output
Air-CooledModel
Water-CooledModel
Cut-out
412±21 PSIG
1301SRH3 remote air-cooled
e KM
Transformer Output
10.5V at
C. Performance Data
APPROXIMATE ICE
APPROXIMATE ICE
APPROXIMATE ICE
APPROXIMATE ICE
APPROXIMATE ICE
IV. Service Diagnosis
A.Diagnostic Procedure
31-MinuteFill Cycle – LED 4 is on. WV and X2 relay auxiliary code T-0,U‑0
5Freeze Cycle – LED 1 is on. Comp and FMR remain energized, PM energizes or remains energized depending on harvest pump timer S4 dip switch 7 setting. FM and LLV energize. HGV, and X1 relay auxiliary code T‑0, U-0,X10 relay auxiliary code U‑1 and later de‑energize. The unit is held in freeze by a 5-minuteshort cycle protection timer CB will not accept a signal from F/S. After the 5-minuteshort cycle protection timer expires, CB turns freeze termination over to F/S. During the first 5 minutes of freeze, confirm that the evaporator temperature drops. After
8Shutdown
B. Control Board Check
1. Float Switch Check
D.Float Switch Check and Cleaning
C. Bin Control Check
2.Float Switch Cleaning
Fig.
E.Thermistor Check
F. Diagnostic Charts
1. No Ice Production
1 The icemaker will not
3 Compressor will
2. Evaporator is Frozen Up
1Freeze cycle time is
3. Low Ice Production
4. Abnormal Ice
5. Other
A.Service for Refrigerant Lines
V. Removal and Replacement of Components
1.Refrigerant Recovery
2. Brazing
3.Evacuation and Recharge R-404A
B.Removal and Replacement of Compressor
C.Removal and Replacement of Expansion Valve
11Place the expansion valve cover in position
E. Removal and Replacement of Evaporator
F. Removal and Replacement of Air-CooledCondenser
1Turn off the power supply 2Remove the panels
1Turn off the power supply
water‑cooled model
Regulator - C.P.R. remote air-cooledmodel
L.Removal and Replacement of Thermistor
Fig.
N.Removal and Replacement of Inlet Water Valve
remote air‑cooled models
O. Removal and Replacement of Pump Motor
Fig.
P. Removal and Replacement of Control Board
VI. Cleaning and Maintenance
A. Cleaning and Sanitizing Instructions
1.Cleaning Procedure
18Replace the front panel in its correct position
B. Maintenance Instructions
C. Preparing the Icemaker for Long Storage
1. Stainless Steel Exterior
2.Storage Bin and Scoop
Fig.
3.Drain the water tank