Hoshizaki KM-1301SRH/3, KM-1301SAH/3, KM-1301SWH/3 service manual C. Performance Data

Models: KM-1301SWH/3 KM-1301SRH/3 KM-1301SAH/3

1 84
Download 84 pages 2.34 Kb
Page 43
Image 43

C. Performance Data

1. KM-1301SAH (air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

 

70/21

 

 

90/32

 

 

 

 

70/21

 

1329

603

 

1281

581

 

1188

539

 

 

 

 

80/27

 

1292

586

 

1217

552

 

1109

503

lbs./day

 

kg./day

90/32

 

1281

581

 

1164

528

 

1060

481

 

100/38

 

1253

568

 

1140

517

 

965

438

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

2160

 

 

 

2166

 

 

2222

CONSUMPTION

80/27

 

2164

 

 

 

2174

 

 

2257

 

 

 

 

90/32

 

2166

 

 

 

2180

 

 

2253

watts

 

 

 

100/38

 

2193

 

 

 

2197

 

 

2320

APPROXIMATE WATER

70/21

 

605

2.29

 

481

1.82

 

429

1.62

CONSUMPTION PER 24 HR.

80/27

 

510

1.93

 

318

1.21

 

331

1.25

 

 

m3/day

90/32

 

481

1.82

 

183

0.69

 

167

0.63

gal./day

 

100/38

 

345

1.30

 

179

0.68

 

152

0.58

FREEZING CYCLE TIME

70/21

 

31

 

 

 

32

 

 

35

 

 

 

 

80/27

 

32

 

 

 

34

 

 

37

 

 

 

 

90/32

 

32

 

 

 

35

 

 

38

min.

 

 

 

100/38

 

33

 

 

 

36

 

 

41

HARVEST CYCLE TIME

70/21

 

4.7

 

 

 

3.9

 

 

3.7

 

 

 

 

80/27

 

4.1

 

 

 

2.9

 

 

3.1

 

 

 

 

90/32

 

3.9

 

 

 

2.1

 

 

2.1

min.

 

 

 

100/38

 

3.1

 

 

 

2.1

 

 

2.1

HEAD PRESSURE

70/21

 

255

17.9

 

273

19.2

 

298

20.9

 

 

 

 

80/27

 

269

18.9

 

297

20.9

 

321

22.6

 

 

 

 

90/32

 

273

19.2

 

317

22.3

 

342

24.0

PSIG

kg/cm2G

100/38

 

278

19.5

 

323

22.7

 

365

25.7

SUCTION PRESSURE

70/21

 

50

3.5

 

50

3.5

 

53

3.8

 

 

 

 

80/27

 

50

3.5

 

50

3.5

 

55

3.9

 

 

 

 

90/32

 

50

3.5

 

50

3.5

 

55

3.8

PSIG

kg/cm2G

100/38

 

52

3.6

 

51

3.6

 

59

4.1

TOTAL HEAT OF REJECTION FROM CONDENSER

 

20,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

Note:

1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

43