B. Sequence of Operation

IMPORTANT

KM-1301SAH-E utilizes a thermostatic bin control. For KM-1301SAH-E operation, the K4 jumper (4A4883G01) must be in place on the control board RED K4 connector or the unit will not operate.

1. Sequence Cycles and Shutdown

The steps in the sequence are as outlined below. When power is supplied, CB red "POWER OK" LED and green "BC CLOSED" LED come on. If red "POWER OK" LED is off on KM-1301SAH-E, clear ice away from the thermostatic bin control bulb in the storage bin area. If yellow "BC OPEN" LED is on, the unit will not start. In this case check that CB has the K4 jumper in place on CB RED K4 connector (KM-1301SAH-E) or clear ice away from the mechanical bin control actuator paddle in the storage bin area (KM1301SWH-E, KM-1301SRH-E). There is a 5-second delay before startup. Note that the order of the component LEDs from the outer edge of CB is 1, 4, 3, 2.

a)1-Minute Fill Cycle

LED 4 is on. WV and X2 relay (auxiliary code T-0, U-0), X11 relay (auxiliary code

U-1 and later) energize and the 1-minute fill cycle begins. After 1 minute, CB checks for a closed F/S. If F/S is closed, the harvest cycle begins. If not, WV remains energized through additional 1-minute fill cycles until water fills the tank and closes F/S. This serves as a low water safety to protect PM.

b)Initial Harvest Cycle

LEDs 1, 4, and 2 are on. WV and X2 relay (auxiliary code T-0, U-0), X11 relay (auxiliary code U-1 and later) remain energized, HGV, X1 relay (auxiliary code T-0, U-0), X10 relay (auxiliary code U-1 and later), Comp, and FMR energize. CB monitors the warming of the evaporator via the thermistor located on the suction line. When the thermistor reaches

48°F (9°C), CB reads a 3.9 kΩ signal from the thermistor and turns harvest termination over to the harvest timer (S4 dip switch 1 & 2). The harvest timer has settings of 60, 90,

120, and 180 seconds. For details, see "II.C.2.b) Harvest Timer (S4 dip switch 1 & 2)."

WV is energized during harvest for a maximum of 6 minutes or the length of harvest minus 0 or 50 seconds (harvest pump timer (S4 dip switch 7)), whichever is shorter.

CAUTION! Do not adjust S4 dip switch 7 out of the factory default position on this model. Adjustment outside of the factory default position may result in damage to the icemaker. For details, see "II.C.2.e) Harvest Pump Timer (S4 dip switch 7)." LED 4 goes off when WV and X2 relay (auxiliary code T-0, U-0), X11 relay (auxiliary code

U-1 and later) de-energize. LED 3 comes on and PM energizes and runs for the last 0 or 50 seconds of harvest depending on S4 dip switch 7 setting. This circulates water over the evaporator for the last 0 or 50 seconds of harvest. PM is energized through the #5 pin (DBu wire) on the CB K1 ten-pin connector and the X1 relay (auxiliary code T0, U-0),

X10 relay (auxiliary code U1 and later). When the harvest timer terminates, the harvest cycle is complete. CB checks the position of F/S and proceeds to the freeze cycle if it is closed or calls for a 1minute fill cycle if it is open. The minimum total time allowed by CB for a complete harvest cycle is 2 minutes.