3. KM-1301SRH-E (remote air-cooled)
APPROXIMATE ICE | AMBIENT TEMP. |
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
| 50/10 |
|
| 70/21 |
|
| 90/32 | |||
|
|
|
|
|
|
|
|
| ||||
|
|
|
| 70/21 | 1270 | 576 |
| 1233 | 559 |
| 1160 | 526 |
|
|
|
| 80/27 | 1241 | 563 |
| 1183 | 537 |
| 1100 | 499 |
lbs./day |
| kg./day | 90/32 | 1233 | 559 |
| 1142 | 518 |
| 1062 | 482 | |
| 100/38 | 1211 | 549 |
| 1123 | 509 |
| 988 | 448 | |||
|
|
|
|
|
|
|
|
|
|
|
| |
APPROXIMATE ELECTRIC | 70/21 |
| 1950 |
|
| 1985 |
|
| 2028 | |||
CONSUMPTION | 80/27 |
| 1977 |
|
| 2031 |
|
| 2071 | |||
|
|
|
|
|
|
|
|
| ||||
|
|
|
| 90/32 |
| 1985 |
|
| 2070 |
|
| 2112 |
watts |
|
|
| 100/38 |
| 1992 |
|
| 2080 |
|
| 2150 |
APPROXIMATE WATER | 70/21 | 544 | 2.06 |
| 451 | 1.71 |
| 396 | 1.50 | |||
CONSUMPTION PER 24 HR. | 80/27 | 473 | 1.79 |
| 330 | 1.25 |
| 314 | 1.19 | |||
|
|
|
|
|
| |||||||
|
| m3/day | 90/32 | 451 | 1.71 |
| 228 | 0.86 |
| 194 | 0.74 | |
gal./day |
| 100/38 | 342 | 1.30 |
| 220 | 0.83 |
| 163 | 0.62 | ||
FREEZING CYCLE TIME | 70/21 |
| 33 |
|
| 34 |
|
| 36 | |||
|
|
|
| 80/27 |
| 34 |
|
| 36 |
|
| 38 |
|
|
|
| 90/32 |
| 34 |
|
| 37 |
|
| 40 |
min. |
|
|
| 100/38 |
| 35 |
|
| 38 |
|
| 42 |
HARVEST CYCLE TIME | 70/21 |
| 4.7 |
|
| 4.1 |
|
| 3.8 | |||
|
|
|
| 80/27 |
| 4.2 |
|
| 3.3 |
|
| 3.2 |
|
|
|
| 90/32 |
| 4.1 |
|
| 2.6 |
|
| 2.4 |
min. |
|
|
| 100/38 |
| 3.4 |
|
| 2.6 |
|
| 2.3 |
HEAD PRESSURE | 70/21 | 210 | 14.8 |
| 225 | 15.8 |
| 238 | 16.7 | |||
|
|
|
| 80/27 | 221 | 15.6 |
| 244 | 17.2 |
| 254 | 17.8 |
|
|
|
| 90/32 | 225 | 15.8 |
| 260 | 18.3 |
| 271 | 19.1 |
PSIG | kg/cm2G | 100/38 | 225 | 15.8 |
| 263 | 18.5 |
| 282 | 19.8 | ||
SUCTION PRESSURE | 70/21 | 50 | 3.5 |
| 51 | 3.6 |
| 55 | 3.8 | |||
|
|
|
| 80/27 | 51 | 3.6 |
| 52 | 3.7 |
| 57 | 4.0 |
|
|
|
| 90/32 | 51 | 3.6 |
| 53 | 3.7 |
| 58 | 4.1 |
PSIG | kg/cm2G | 100/38 | 53 | 3.7 |
| 54 | 3.8 |
| 62 | 4.4 |
TOTAL HEAT OF REJECTION FROM CONDENSER | 18,982 | BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
TOTAL HEAT OF REJECTION FROM COMPRESSOR | 2,600 | BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
CONDENSER VOLUME | 133 | CU. IN |
Note:
1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.
2.We reserve the right to make changes in specifications and design without prior notice.
34