Hoshizaki KM-1301SWH-E, KM-1301SRH-E, KM-1301SAH-E Ice Chute Float Switch Assembly Drain Plug

Models: KM-1301SRH-E KM-1301SWH-E KM-1301SAH-E

1 59
Download 59 pages 18.18 Kb
Page 56
Image 56

5)Remove the drain plug located on the lower front part of the ice chute. See Fig. 6. Allow the water tank to drain.

6)Replace the drain plug in its correct position. Be careful not to cross thread it.

7)In bad or severe water conditions, clean the float switch assembly as described below. Otherwise, continue to step 8.

a.Disconnect the vent tube and the flush tube from the top of the float switch, then remove the float switch assembly. Remove the rubber boot from the bottom of the assembly.

b.Remove the retainer rod from the bottom of the float switch housing, then remove the float. Be careful not to bend the retainer rod excessively when removing it.

c.Wipe down the float switch assembly's housing, shaft, float, and retainer rod with cleaning solution. Clean the inside of the rubber boot and hose with cleaning solution. Rinse the parts thoroughly with clean water.

d.Reassemble the float switch assembly and replace it and the rubber boot in their correct positions. Reconnect the vent tube and the flush tube.

8)Pour the cleaning solution into the water tank.

9)Move the control switch on the control box to the "WASH" position.

10)Replace the insulation panel and the front panel in their correct positions.

11)Turn on the power supply to start the washing process.

12)Turn off the power supply after 30 minutes.

13)Remove the front panel and the insulation panel.

14)Remove the drain plug. Allow the water tank to drain. Replace the drain plug and the insulation panel in their correct positions.

Ice Chute

Float Switch Assembly

Drain Plug

Fig. 6

56

Page 56
Image 56
Hoshizaki KM-1301SWH-E, KM-1301SRH-E, KM-1301SAH-E service manual Ice Chute Float Switch Assembly Drain Plug