3. Low Ice Production

Low Ice Production - Possible Cause

 

Long Harvest Cycle

 

 

1. Evaporator

a) Scaled up.

 

 

2. Spray Tubes and/or Spray

a) Dirty.

Guides

b) Out of position.

 

 

 

3. Refrigerant Charge

a) Low.

 

 

4. Water Supply

a) Low water pressure.

 

 

 

b) External water filters clogged.

 

c) Insufficient water line size.

 

Minimum 3/8" nominal ID (10 mm nominal OD)

 

 

 

d) Too cold.

 

 

5. Control Board

a) Thermistor connection loose (K3).

See "IV.B. Control Board Check."

 

b) Defective.

6. Thermistor

a) Loose, disconnected, or defective.

See "IV.E. Thermistor Check."

 

 

 

7. Hot Gas Valve

a) Erratic or closed.

 

 

8. Inlet Water Valve

a) Water valve screen clogged.

 

 

9. Compressor

a) Inefficient or off.

 

 

10. Liquid Line Valve (if applicable)

a) Erratic or open.

11. Expansion Valve (TXV)

a) Defective.

 

 

12. Water Regulating Valve

a) Leaking by.

(water-cooled model)

 

 

 

 

Long Freeze Cycle

 

 

1. Evaporator

a) Scaled up.

2. Refrigerant Charge

a) Low.

 

 

3. Air Filter (air-cooled model)

a) Clogged.

 

 

4. Condenser (air-cooled and

a) Clogged.

remote air-cooled models)

 

 

 

5. Condenser (water-cooled model)

a) Water temperature out of specification.

6. Control Board

a) Float switch connection loose (K5).

See "IV.B. Control Board Check."

 

b) Defective.

 

 

7. Hot Gas Valve

a) Erratic or open.

 

 

8. Inlet Water Valve

a) Leaking by.

9. Float Switch

a) Float does not move freely or defective switch.

See "IV.D. Float Switch Check

 

and Cleaning."

 

 

 

10. Compressor

a) Inefficient or off.

 

 

11. Pump Motor

a) RPM too slow.

 

 

12. Liquid Line Valve (if applicable)

a) Erratic or closed.

13. Expansion Valve (TXV)

a) Bulb loose.

 

 

 

b) Defective.

 

 

14. Headmaster (C.P.R.) (remote

a) Not bypassing.

condenser unit)

 

 

 

15. Water Regulating Valve

a) Out of adjustment.

(water-cooled model)

 

See "IV.F. Adjustment of Water

 

Regulating Valve."

 

50

Page 50
Image 50
Hoshizaki KM-1301SWH-E, KM-1301SRH-E Low Ice Production Possible Cause Long Harvest Cycle, Long Freeze Cycle