C. Control Board

A Hoshizaki exclusive solid-state control board is employed in Hoshizaki Stackable Crescent Cubers.

All models are pretested and factory set.

CAUTION

1.The control board is fragile; handle very carefully.

2.The control board contains integrated circuits, which are susceptible to failure due to static discharge. It is especially important to touch the metal part of the unit before handling or replacing the control board.

3.Do not touch the electronic devices on the control board or the back of the control board.

4.Do not change wiring and connections. Do not misconnect K3, K4, and K5, because the same connector is used for the thermistor, jumper (KM1301SAH-E) or mechanical bin control (KM-1301SWH-E,

KM1301SRH-E), and float switch. KM-1301SAH-E utilizes a thermostatic bin control. For KM-1301SAH-E operation, the K4 jumper (4A4883G01) must be in place on the control board RED K4 connector.

5.Always replace the whole control board assembly if it goes bad.

6.Do not short out power supply to test for voltage.

18

Page 18
Image 18
Hoshizaki KM-1301SRH-E, KM-1301SAH-E, KM-1301SWH-E service manual Control Board