a)LED Lights and Audible Alarm Safeties
At startup, a
The red LED indicates proper control voltage and remains on unless a control voltage problem occurs. The green LEDs 1 through 4 energize and sequence from initial startup as listed in the table below. Note that the order of the LEDs from the outer edge of the control board is 1, 4, 3, 2. For details, see "II.B. Sequence of Operation."
| Sequence Step |
| LED |
| Energized |
|
|
| Time LEDs are On | |||||
|
|
| Components |
|
| Min. |
| Max. |
| Avg. | ||||
|
|
|
|
|
|
|
|
|
|
| ||||
4 |
| WV |
|
|
|
|
| 1 minute | ||||||
Harvest Cycle | 1, 4, 2 |
| Comp, FMR, WV, |
| 2 minutes | 20 minutes | 3 to 5 minutes | |||||||
|
|
|
|
|
| HGV |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Harvest Pump Timer | 1, 3, 2 |
| Comp, FMR, PM, |
| 0 seconds | 50 seconds | harvest pump timer | |||||||
|
|
|
|
|
| HGV |
|
|
|
|
| setting | ||
Freeze Cycle | 1 |
| Comp, FM/FMR, |
| 5 minutes | freeze timer | 30 to 35 minutes | |||||||
|
|
|
|
|
| PM, LLV |
|
|
| setting |
|
| ||
1, 4*, 3, 2 | Comp, FMR, WV*, |
| 10 seconds | 20 seconds | ||||||||||
|
|
|
|
|
| PM, HGV |
|
|
|
|
| setting |
The
No. of Beeps | Type of Alarm | Notes | |
(every 3 sec.) | |||
|
| ||
|
|
| |
1 | High Evaporator Temp. | Check for harvest problem (stuck HGV or relay), hot | |
| (temperature > 127°F (53°C)) | water entering unit, stuck HM, or shorted thermistor. | |
2 | Harvest Backup Timer | Check for open thermistor, HGV not opening, TXV or | |
| (harvest > 20 min. for two cycles | LLV leaking by, low charge, inefficient Comp., or WRV | |
| in a row) | leaking by. | |
3 | Freeze Timer | Check for F/S stuck closed (up), WV leaking by, HGV | |
| (freeze > freeze timer setting for | leaking by, PM not pumping, TXV not feeding properly, | |
| two cycles in a row) | LLV not opening, low charge, HM not bypassing, or | |
| Timer is factory set using S4 dip | inefficient Comp. | |
| switch 9 & 10 |
| |
To reset the above safeties, press the "ALARM RESET" button with the power supply on. | |||
|
|
| |
6 | Low Voltage | Red LED turns off if voltage protection operates. | |
| (92Vac±5% or less) | The control voltage safeties automatically reset when | |
7 | High Voltage | voltage is corrected. | |
| (147Vac±5% or more) |
|