Hoshizaki KM-1301SWH-E, KM-1301SRH-E, KM-1301SAH-E service manual Performance Data

Models: KM-1301SRH-E KM-1301SWH-E KM-1301SAH-E

1 59
Download 59 pages 18.18 Kb
Page 32
Image 32

C. Performance Data

1. KM-1301SAH-E (air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

 

70/21

 

 

90/32

 

 

 

 

70/21

 

1114

505

 

1082

491

 

992

450

 

 

 

 

80/27

 

1089

494

 

1039

471

 

924

419

lbs./day

 

kg./day

 

90/32

 

1082

491

 

1004

455

 

897

407

 

 

100/38

 

1048

475

 

979

444

 

799

362

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1900

 

 

 

1964

 

 

2009

CONSUMPTION

80/27

 

1949

 

 

 

2049

 

 

2069

 

 

 

 

90/32

 

1964

 

 

 

2120

 

 

2151

watts

 

 

 

100/38

 

1958

 

 

 

2127

 

 

2180

APPROXIMATE WATER

70/21

 

537

2.03

 

426

1.61

 

377

1.43

CONSUMPTION PER 24 HR.

80/27

 

452

1.71

 

279

1.06

 

288

1.09

 

 

m3/day

90/32

 

426

1.61

 

157

0.59

 

140

0.53

gal./day

 

100/38

 

302

1.14

 

153

0.58

 

125

0.47

FREEZING CYCLE TIME

70/21

 

34

 

 

 

35

 

 

39

 

 

 

 

80/27

 

35

 

 

 

38

 

 

43

 

 

 

 

90/32

 

35

 

 

 

40

 

 

44

min.

 

 

 

100/38

 

37

 

 

 

41

 

 

48

HARVEST CYCLE TIME

70/21

 

4.8

 

 

 

4.0

 

 

3.7

 

 

 

 

80/27

 

4.2

 

 

 

2.9

 

 

3.2

 

 

 

 

90/32

 

4.0

 

 

 

2.1

 

 

2.1

min.

 

 

 

100/38

 

3.1

 

 

 

2.1

 

 

2.1

HEAD PRESSURE

70/21

 

275

19.3

 

293

20.6

 

316

22.2

 

 

 

 

80/27

 

289

20.3

 

318

22.3

 

338

23.8

 

 

 

 

90/32

 

293

20.6

 

338

23.8

 

360

25.3

PSIG

kg/cm2G

100/38

 

297

20.9

 

343

24.1

 

380

26.7

SUCTION PRESSURE

70/21

 

57

4.0

 

58

4.1

 

61

4.3

 

 

 

 

80/27

 

58

4.1

 

59

4.2

 

64

4.5

 

 

 

 

90/32

 

58

4.1

 

60

4.2

 

64

4.5

PSIG

kg/cm2G

100/38

 

59

4.2

 

61

4.3

 

68

4.8

TOTAL HEAT OF REJECTION FROM CONDENSER

 

19,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

Note:

1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

32

Page 32
Image 32
Hoshizaki KM-1301SWH-E, KM-1301SRH-E, KM-1301SAH-E service manual Performance Data