S2 Dip Switch Setting

Anti-Slush Control

No. 6

 

OFF

Activated (Ver. 1.0)

ON

Deactivated

Control Board P01771-02

k) Harvest Promotion Control (S2 dip switch 2) [Program Ver. 3.1, Ver. 3.2]

Do not adjust. This must be left in the factory default position or the unit will not operate properly.

It is deactivated on the KMD-410 series.

When activated, this control promotes harvest of ice on the evaporator that is hard to remove. If the harvest cycle exceeds 6 minutes, the pump motor starts to operate for a maximum of 3 minutes.

S2 Dip Switch Setting

Harvest Promotion

No. 2

Control

OFF

Activated

ON

Deactivated

l) Refill Counter (S2 dip switch 3) [Program Ver. 3.1, Ver. 3.2]

Do not adjust. This must be left in the factory default position or the unit will not operate properly. The KMD-410MAH and KMD-410MWH refill 1 time.

m) Harvest Completion Detection Control (S2 dip switch 4) [Program Ver. 3.1, Ver. 3.2]

Do not adjust. This must be left in the factory default position or the unit will not operate properly.

It is deactivated on the KMD-410 series.

When activated, this control determines whether ice remains on the evaporator at the end of a harvest cycle and at the beginning of a freeze cycle. If ice drops and activates the bin control switch in the last 10 seconds of a harvest cycle, the control determines that ice still remains on the evaporator and extends the harvest cycle for 30 seconds. If the bin control switch is activated at the beginning of a freeze cycle, the control determines that ice still remains on the evaporator and starts a harvest cycle after the minimum freeze cycle time has passed.

S2 Dip Switch Setting

Harvest Completion

No. 4

Detection Control

OFF

Deactivated

ON

Activated

n) Overfreeze Detection Control (S2 dip switch 5) [Program Ver. 3.1, Ver. 3.2]

Do not adjust. This must be left in the factory default position or the unit will not operate properly.

It is deactivated on the KMD-410 series.

When activated, the thermistor detects the temperature of the evaporator outlet to find overfreeze in a harvest cycle and at the beginning of a freeze cycle. If the difference between the maximum temperature after the water saver timer starts counting and the