Hoshizaki KMD-410MWH manual Performance Data, a KMD-410MAH

Models: KMD-410MWH KMD-410MAH

1 65
Download 65 pages 49.57 Kb
Page 29
Image 29

4. PERFORMANCE DATA

[a] KMD-410MAH

APPROXIMATE ICE

AMBIENT

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

 

 

 

TEMP. (ºF/ºC)

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

 

 

 

 

 

 

 

70/21

415

188

 

388

176

 

354

160

 

 

 

80/27

395

179

 

353

160

 

320

145

 

 

 

90/32

388

176

 

324

147

 

289

131

lbs./day

kg./day

100/38

382

173

 

316

143

 

257

117

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

710

 

 

731

 

 

753

CONSUMPTION

 

 

 

 

 

80/27

 

726

 

 

758

 

 

776

 

 

 

 

 

 

 

 

 

 

 

90/32

 

731

 

 

780

 

 

801

watts

 

 

100/38

 

733

 

 

785

 

 

820

APPROXIMATE WATER

70/21

148

0.56

 

126

0.48

 

114

0.43

CONSUMPTION PER 24

 

 

80/27

131

0.50

 

97

0.37

 

95

0.36

HR.

 

 

 

 

 

 

90/32

126

0.48

 

73

0.28

 

67

0.25

 

 

 

 

 

gal./day

m3/day

100/38

101

0.38

 

72

0.27

 

61

0.23

FREEZING CYCLE TIME

70/21

 

27

 

 

29

 

 

32

 

 

 

 

 

 

 

 

 

 

 

80/27

 

28

 

 

31

 

 

34

 

 

 

90/32

 

29

 

 

34

 

 

37

min.

 

 

100/38

 

29

 

 

34

 

 

40

HARVEST CYCLE TIME

70/21

 

3.0

 

 

2.7

 

 

2.6

 

 

 

 

 

 

 

 

 

 

 

80/27

 

2.8

 

 

2.3

 

 

2.4

 

 

 

90/32

 

2.7

 

 

2.0

 

 

2.0

min.

 

 

100/38

 

2.4

 

 

2.0

 

 

2.0

HEAD PRESSURE

70/21

216

15.2

 

237

16.7

 

261

18.4

 

 

 

 

 

 

 

 

80/27

232

16.3

 

265

18.6

 

287

20.2

 

 

 

90/32

237

16.7

 

288

20.2

 

311

21.9

PSIG

kg/cm2G

100/38

240

16.9

 

293

20.6

 

333

23.4

SUCTION PRESSURE

70/21

45

3.2

 

48

3.3

 

52

3.6

 

 

 

 

 

 

 

 

80/27

47

3.3

 

51

3.6

 

55

3.9

 

kg/cm2G

90/32

48

3.3

 

54

3.8

 

58

4.1

PSIG

100/38

49

3.4

 

55

3.9

 

62

4.4

TOTAL HEAT OF REJECTION FROM CONDENSER

6,000 BTU/h

[AT 90ºF (32ºC) / WT 70ºF (21ºC)]

Note: Pressure data is recorded at 5 minutes into freezing cycle.

The data not in bold should be used for reference only.

We reserve the right to make changes in specifications and design without prior notice.

25

Page 29
Image 29
Hoshizaki KMD-410MWH manual Performance Data, a KMD-410MAH