8)Connect the bin control connector to the side of the control box.
9)Replace the water tank, cube guide, pump motor bracket, pump motor and float switch in their correct positions until they snap in place.
CAUTION
Be sure to let the discharge hose pass behind the copper tube and connect it securely in position. Otherwise, the discharge hose may be caught in the front insulation, leading to improper results.
10)Secure the pump motor bracket with the two thumbscrews.
11)Reconnect the pump motor connector and float switch connector.
12)Replace the front insulation and front panel in their correct positions.
13)Turn on the power supply.
17. THERMISTOR
1)Turn off the power supply.
2)Remove the panels.
3)Disconnect the connector of the thermistor lead (orange).
4)Remove the ties, insulation, thermistor holder, and thermistor in this order.
5)Remove the old sealant from the thermistor holder and suction pipe.
6)Wipe off any moisture or condensation from the suction pipe surfaces.
7)Press a tube of the sealant KE 60RTV, manufactured by
49