I. SPECIFICATIONS

I. SPECIFICATIONS

1. SPECIFICATIONS

[a] KMD-410MAH (air-cooled)

AC SUPPLY VOLTAGE

115/60/1

 

 

 

AMPERAGE

 

8.0 A (5 Min. Freeze AT 104°F / WT 80°F)

 

MINIMUM CIRCUIT AMPACITY

15 A

 

 

 

 

MAXIMUM FUSE SIZE

15 A

 

 

 

 

APPROXIMATE ICE PRODUCTION

Ambient

WATER TEMP. (°F)

PER 24 HR.

 

Temp.(°F)

50

 

70

90

lbs./day (kg/day)

70

*415 (188)

 

388 (176)

354 (160)

Reference without *marks

80

395 (179)

 

353 (160)

320 (145)

 

 

90

388 (176)

 

*324 (147)

289 (131)

 

 

100

382 (173)

 

316 (143)

257 (117)

SHAPE OF ICE

 

Crescent Cube

 

 

 

 

ICE PRODUCTION PER CYCLE

8.5 lbs. (3.9 kg) 416 pcs.

 

 

APPROXIMATE STORAGE CAPACITY

N/A

 

 

 

 

ELECTRIC & WATER CONSUMPTION

90/70°F

 

 

70/50°F

 

ELECTRIC

W (kWH/100 lbs.)

780(5.8)

 

 

710(4.1)

 

WATER

gal./24HR (gal./100 lbs.)

73(22.6)

 

 

148(35.7)

 

EXTERIOR DIMENSIONS (WxDxH)

22-1/4" x 24-1/8" x 24" (565 x 613 x 610 mm)

 

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

 

WEIGHT

 

Net 126 lbs. (57 kg), Shipping 161 lbs. (73 kg)

 

CONNECTIONS - ELECTRIC

Permanent - Connection

 

 

 

- WATER SUPPLY

Inlet

1/2" FPT

 

 

 

- DRAIN

Outlet

3/4" FPT

 

 

CUBE CONTROL SYSTEM

Float Switch

 

 

 

 

HARVESTING CONTROL SYSTEM

Hot Gas and Water, Thermistor and Timer

 

ICE MAKING WATER CONTROL

Timer Controlled, Overflow Pipe

 

 

COOLING WATER CONTROL

N/A

 

 

 

 

BIN CONTROL SYSTEM

Mechanical Level Switch with Delay

 

COMPRESSOR

Hermetic, Model NT6217GKV

 

 

CONDENSER

 

Air-Cooled, Fin and tube type

 

 

EVAPORATOR

 

Vertical type, Stainless Steel and Copper

 

REFRIGERANT CONTROL

Thermostatic Expansion Valve

 

 

REFRIGERANT CHARGE

R-404A, 1 lb. 2.3 oz. (520g)

 

 

DESIGN PRESSURE

High 467PSIG, Low 206PSIG

 

 

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-out (Internal)

 

 

COMPRESSOR PROTECTION

Auto-reset Overload Protector (Internal)

 

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

 

LOW WATER PROTECTION

Float Switch

 

 

 

 

ACCESSORIES - SUPPLIED

N/A

 

 

 

 

 

- REQUIRED

Ice Dispenser or Ice Storage Bin

 

 

OPERATING CONDITIONS

VOLTAGE RANGE

 

104 - 127 V

 

 

AMBIENT TEMP.

 

45 -100° F

 

 

WATER SUPPLY TEMP.

 

45 - 90° F

 

 

WATER SUPPLY PRESSURE

 

10 - 113PSIG

We reserve the right to make changes in specifications and design without prior notice.