Hoshizaki KMD-410MAH manual a CONTROL & SERVICE SWITCH, b FUSE, c FUSE HOLDER, d CONTROL BOARD

Models: KMD-410MWH KMD-410MAH

1 65
Download 65 pages 49.57 Kb
Page 56
Image 56

[a] CONTROL & SERVICE SWITCH

1)Disconnect the tab terminals and remove the nut securing the power switch.

2)Install the new switch in the reverse order of the removal procedure.

3)To prevent miswiring, check the terminal numbers and lead wire colors with the wiring label.

[b] FUSE

1)Use a phillips head screwdriver to remove the fuse holder cap and take out the fuse.

2)Install the new fuse in the reverse order of the removal procedure.

[c] FUSE HOLDER

1)Disconnect the tab terminal and remove the nut securing the fuse holder.

2)Install the new fuse holder in the reverse order of the removal procedure.

[d] CONTROL BOARD

1)Disconnect all the connectors.

2)Remove the four board supports secured to the control box to release the control board.

3)Install the new control board in the reverse order of the removal procedure.

4)Check the dip switch for proper setting.

5)When reconnecting the connectors, do not push them too hard. The control board may be damaged.

[e] MAGNETIC CONTACTOR

1)Disconnect the tab terminals, remove the mounting screw or pull the tub of bracket to release the magnetic contactor, and lift off the magnetic contactor.

2)Install the new magnetic contactor in the reverse order of the removal procedure.

[f] CONTROL BOARD TRANSFORMER

1)Disconnect the connectors and closed end connectors connecting the control board. (The tie securing the harness may be removed. But be careful not to break the lead wires.)

2)Remove the mounting screws.

3)Install the new transformer in the reverse order of the removal procedure.

52

Page 56
Image 56
Hoshizaki KMD-410MAH, KMD-410MWH a CONTROL & SERVICE SWITCH, b FUSE, c FUSE HOLDER, d CONTROL BOARD, e MAGNETIC CONTACTOR