7.Stacking Remote Condenser Units

4)Connect the fan motor leads in the junction box of the remote condenser unit to the fan motor leads in the fan motor junction box of the icemaker. Use wire of an appropriate gage and outdoor rating.

5)Replace the junction box covers and the louver panel in their correct positions.

Fig. 14

Remote Condenser Unit

Junction Box

Cover

Screws

Louver Panel

Icemaker

Fan Motor Junction

Box Cover

Screw

7.Stacking Remote Condenser Units

1)Install the lower remote condenser unit as described earlier in this section.

2)Place the upper remote condenser unit on top of the lower. See Fig. 15.

3)Secure the upper remote condenser unit to the lower remote condenser unit with the 4 screws provided.

4)Install refrigerant lines and make electrical connection as described earlier in this section.

Upper Remote

Condenser Unit