Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 1/2" nominal copper water tubing is recommended for the icemaker water supply line.

An icemaker water supply line shut-off valve and drain valve should be installed.

Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal hard pipe is recommended for the icemaker drain line. Condensation drain outlet is 3/8" OD hard tube. The condensation drain line can be connected to the icemaker drain line or can be run separately.

Remote Condenser Line Set Connections

Minimum 1/2" Nominal Copper Water Tubing

Icemaker

Water Supply

Inlet

1/2" FPT

Icemaker

Drain Outlet

3/4" FPT

Vent Tube

Icemaker

Bin

Icemaker Water Supply

Line Shut-Off Valve

Condensation

Drain Outlet

3/8" OD Hard Tube

KMH-2000SRH/3Manual backgroundManual background Icemaker Water Supply Line

Drain Valve

Manual background Minimum 3/4" Nominal Hard Pipe

Bin Drain Outlet

See Manufacturer's Instructions

Separate piping to approved drain. Leave a 2-inch (5-cm) vertical air gap between the end of each pipe and the drain.

Manual backgroundManual background Vent Tube

2-inch (5-cm) air gap

Fig. 16

KMH-2000SRH/3

Floor Drain

25