![c)Minimum regulation of the hob burners:](/images/new-backgrounds/56199/5619911x1.webp)
Installation
c)Minimum regulation of the hob burners:
GB
•turn the tap to minimum;
•remove the knob and adjust the regulation screw, which is positioned in or next to the tap pin, until the flame is small but steady.
!In the case of liquid gas, the
regulation screw must be screwed in to the bottom.
•check that the flame does not turn off when you turn the tap quickly from high to low.
d ) Regulating the primary air of the burners: The primary air of the burners requires no regulation.
Adapting to different types of gas (main and top oven)
In order to adapt the oven to a different type of gas with respect to the gas for which it was manufactured (indicated on the label), follow these simple steps:
a)Replacing the oven burner nozzle
• open the oven door fully
• pull out the sliding oven bottom
•unscrew the two screws and take off the shield protecting the burner (in main oven burner only).
b ) Minimum regulation of the main and top gas oven burner with thermostat:
•light the burner as described in the
paragraph | the oven knob” of the |
instruction booklet. |
|
•turn the knob to Max for about 10 minutes
and then turn the knob to the Min
setting;
•remove the knob;
•regulate the screw positioned outside the
thermostat pin until the flame is steady.
!In the case of liquid gas, the regulation screw must be screwed in to the bottom.
•check that the burner does not turn off when you turn the knob from Max to Min and and when you open and close the oven door quickly.
Adapting the gas grill to different types of gas Replacing the nozzle of the grill burner:
V
Z
• | Remove the enamelled baffle at the front of |
| the grill (2 screws). |
• | Remove the screw on the right hand side of the |
| burner and gently slide the burner off the injector. |
• | Using a 7mm socket, replace the grill injector as |
V
•Pry the fixing tab “V” and remove the oven burner
•Unscrew the oven burner nozzle using the socket spanner for the nozzles “Z”, or a 7 mm socket spanner, and replace it with a nozzle suited to the new type of gas (see Table 1).
Take particular care handling the spark plug wires and the thermocouple pipes.
•Replace all the parts, following the steps described above in the reverse order.
appropriate (see table 1). |
• |
!On completion of the operation, replace the old rating sticker with one indicating the new type of gas used. This sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to “regulators for channelled gas”.
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
6