HP 410C manual Bnc

Models: 410C

1 63
Download 63 pages 50.05 Kb
Page 34
Image 34

TM 11-6625-1614-15

Section V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model 410C

 

 

Table 5-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5-1. Recommended Test Equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instrument Type

Required

 

 

Characteristics

 

Use

 

 

Recommended

Model

 

 

 

 

 

 

 

 

 

 

Voltmeter Calibrator

Range: .015 to 300 v

AC and DC Accuracy

@ Model 738BR Volt-

 

 

 

 

 

Frequency:

 

 

DC and 400 cps

Checks and Calibration

meter Calibrator

 

 

 

 

 

Accuracy:

+0.

370

AC

Adjustments

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*O. 2%0

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Power

Supp Iy

Range: O to 10 v continuous

DC Ammeter Accuracy

@Model 723A DC Power

 

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

Checks

 

 

 

 

supply

 

 

 

i

 

DC Voltmeter

Range:

10

 

v

 

 

Accumcy

 

Checks; Power

@ Model 3440A/3442A

 

 

 

 

 

 

 

 

 

 

Accuracy:

 

+0.

2%

 

Supply Measurements;

Digital

Voltmeter

 

 

 

 

 

 

 

 

 

 

 

 

 

Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

Response

Frequency:

 

 

20 cps to 10 Mc

Frequency

Response

Test

@ Model 739AR Freq-

 

.

Test Set

 

with external oscillator

 

 

 

 

 

uency Response

Test

 

 

 

 

 

 

 

 

 

 

 

 

 

Output: 2 v into 50 ohms

 

 

 

 

 

Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oscillator

 

Frequency:

 

 

20 cps to 10 Mc

Frequency

Response

Test

@

Model 651A

Test

 

 

 

 

output

: 2.0

v

 

 

 

 

 

 

 

Oscillator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF Signal

Generator

Frequency:

 

 

10 Mc to 480 Mc

Frequency

Response

Test

@ Model

608C RFSigmal

 

 

 

 

 

output:

1.0

v

 

 

 

 

 

 

 

Generator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Meter

Frequency:

 

 

10Mc to700 Mc

Frequency

Response

Test

@ Model 431B Power

 

 

 

 

 

Range:

1.0

 

v

 

 

 

 

 

 

 

Meter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VHF Signal Generator

Frequency:

 

 

480 Mc to 700Mc

Frequency

Response

Test

@

Model 612A VHF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal

Generator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC Voltmeter

Range:

115

 

V

 

 

Power Supply

Measure-

@ Model

3400A RMS

 

 

 

 

 

 

 

 

 

 

 

 

 

ments

(ripple)

 

Voltmeter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electronic

Counter

Frequency

 

 

Range: to at

Chopper

Frequency

Adjust

@ Model 521C Electronic

 

 

 

 

 

least

102

 

cps

 

 

 

 

 

 

Counter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Standard

output:

1000

v

 

DC Adjust

 

 

 

@

Model 740A

DC

 

 

 

 

 

Accuracy:

 

+0.

2%

 

 

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ohmmeter

 

Range:

100

 

Mf2

 

Troubleshooting

 

@ Model 412A DC VTVM

 

 

 

 

 

Accuracy:

 

 

+5%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermistor Mount

Frequency:

 

 

10 Mc to 700Mc

Frequency

Response

Test

@? Model 478A Coaxial

 

 

 

 

 

Impedance:

 

 

50 ohm match

 

 

 

 

 

Thermistor Mount

 

 

 

 

 

 

 

 

 

 

 

 

Pr~be-T-Connector

For use with 50 ohm trans-

Frequency

Response

Test

@ Model 11042A Probe-

 

 

 

 

 

mission

line

 

 

 

 

 

 

 

T-Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 KC Filter

High pass fi 1 ter capable of

Frequency

Response

Test

@ Model K02-411A

 

 

 

 

 

10

kc

re]ection

 

 

 

 

 

 

 

10 KC Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector

Adapter

Male

BNC to male

BNC

Frequency

Response

Test

@ Part No. 1250-0216

 

 

 

 

 

 

 

 

 

 

 

 

Connector

Adapter

Type N male to BNC female

Frequency Response

Test

@ Part No. 1250-0067

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistors:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 M!l

 

Accuracy:

 

 

*1%

 

Performance

Checks

& Part No. 0730-0168

 

 

 

5 MQ

 

Accuracy:

 

 

+1%

 

Performance

Checks

@ Part No. 0730-0125

 

 

 

4,5Mfl

 

Accuracy:

 

 

+1%

 

Performance

Checks

@ Part No. 0730 -015’7

 

 

 

500 K

 

Accuracy:

 

 

+1%

 

Performance

Checks

@ Part No. 0721-0011

 

 

 

56 K

 

Accuracy:

 

 

*1%

 

Performance

Checks

@ Part No. 0730-0053

 

 

 

10 K

 

Accuracy:

 

 

+1%

 

Performance

Checks

@ Part No. 0727-0157

 

 

 

9K

 

Accuracy:

 

 

*I?o

 

Performance

Checks

@ Part No. 0730-0026

 

 

 

1.5K

 

Accuracy:

 

 

*1%

 

Performance

Checks

@ Part No. 0730 -001’7

 

 

 

56 ohms

 

Accuracy:

 

 

+1%

 

Performance

Checks

@ Part No. 0811-0341

 

 

 

10 ohms

 

Accuracy:

 

 

*170

 

Performance

Checks

@ Part No. 0727-0335

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-0

01556-2

Page 34
Image 34
HP 410C manual Bnc