HP NetRAID-4M Cluster Services Installation Guide

Hardware, Drivers and Utilities

2.2Install the NetRAID-4M and Heartbeat NIC

1.Power off both Server A and Server B.

2.Disconnect all cables from the back of Server A.

3.If working on a racked server, extend the rack enclosure foot.

4.Extend Server A and open the cover to gain access to the PCI slots.

5.Insert an HP D5013B NIC into any 32-bit slot available in the server:

6.Verify that the HP NetRAID-4M termination jumpers are installed as shown in the following graphic.

Jumpers

7. Verify the Battery Enable Jumper is properly installed on both pins as shown below.

NOTE Note: The card ships from HP with this jumper installed on only one of the two pins.

8.Insert the HP NetRAID-4M into any 64-bit PCI slot available in the server.

9.Close Server A and if working on a racked server, slide the server back into the rack enclosure.

10.Reconnect the video, keyboard, mouse, power, and network cables.

6

Page 10
Image 10
HP NetServer NetRAID-4M manual Install the NetRAID-4M and Heartbeat NIC