Overview

Before you begin

For more information on site requirements, specifications, power requirements, management requirements, and supported facility connections, see the HP Performance Optimized Datacenter 40c G2 Site Preparation and Requirements Guide.

The actual location of various components or included subsystems in your HP POD 40c G2 might vary from what is described in this document. For information specific to your HP POD 40c G2, see the drawings included in the Operations and Maintenance Manual for the HP Performance Optimized Datacenter 40c G2.

Operator safety

The HP POD 40c G2 provides service access areas for periodic maintenance and service and is only to be used by owner-authorized personnel specifically trained in the maintenance and service of the HP POD 40c G2.

The HP POD 40c G2 is not a habitable structure suitable for long term personnel occupancy.

WARNING: To avoid the risk of personal injury or loss of life, all personnel must comply with PPE requirements when opening or working inside areas of the HP POD 40c G2 that are marked as hazardous voltage, per NFPA 70E in accordance with NEC (NA) and IEC (EMEA and APJ).

WARNING: To avoid the risk of personal injury, hearing protection must be worn at all times when working inside the HP POD 40c G2.

WARNING: To avoid the risk of personal injury or damage to the equipment, do not insert anything inside the electrical busways except the approved HP busway drop boxes.

The customer is responsible for completing any Environmental Health and Safety (EHS) evaluation of the HP POD 40c G2 or any attached structural component purchased through HP. The customer must complete an arc flash assessment of the HP POD 40c G2 and the associated electrical supply system for operation, maintenance, and so on.

Component safety

CAUTION: If the HP POD 40c G2 is shut down for an extended period of time, such as during routine maintenance, use desiccant units or materials to eliminate condensation within the HP POD 40c G2. Condensation causes damage to IT equipment and HP POD 40c G2 controls.

CAUTION: Electrostatic discharge might damage electronic components. Be sure that you are properly grounded (earthed) by wearing approved grounding straps before beginning any installation procedure or repair.

Overview 6

Page 6
Image 6
HP Performance Optimized Data Center (POD) 40c manual Overview, Before you begin, Operator safety, Component safety

Performance Optimized Data Center (POD) 40c specifications

The HP Performance Optimized Data Center (POD) 40c is a state-of-the-art data center solution designed to meet the increasing demands for efficiency, scalability, and flexibility in enterprise environments. Aimed at delivering high-performance computing with minimal environmental impact, the POD 40c integrates innovative technologies and features to optimize operations.

One of the standout characteristics of the POD 40c is its modular design, allowing for easy deployment and scalability. Customers can configure their data center according to specific requirements, enabling rapid expansion as business needs evolve. The POD can house up to 240 servers, providing ample capacity to support intensive workloads while ensuring that users can quickly adapt to changing technological landscapes.

The energy efficiency of the POD 40c is a significant highlight. By employing advanced cooling technologies, including hot aisle/cold aisle containment and direct expansion cooling, it minimizes energy consumption while maintaining optimal temperatures for hardware components. This focus on efficiency also extends to power management, with redundant power supplies and the integration of high-efficiency power distribution units (PDUs) that help reduce operational costs.

In terms of connectivity, the HP POD 40c is equipped with comprehensive networking capabilities. The design includes integrated cabling systems that ensure organized and efficient routing of power and data. This dedication to streamlined connectivity facilitates faster data transfer rates and decreases latency, enhancing overall system performance.

Moreover, security is a paramount consideration in the POD 40c design. The unit incorporates various security features, including access controls, environmental monitoring, and surveillance options, which provide peace of mind for data-sensitive businesses. These elements work together to ensure that critical data remains protected from unauthorized access and environmental threats.

Sustainability is another key aspect, as the POD 40c is designed to be environmentally friendly. The system's effective cooling mechanisms and efficient power usage contribute to reduced carbon emissions, aligning with corporate sustainability goals and industry regulations.

In conclusion, the HP Performance Optimized Data Center (POD) 40c represents a cutting-edge solution for modern data center requirements. Its modularity, energy efficiency, robust connectivity, enhanced security, and sustainability make it an attractive option for organizations aiming to optimize their IT infrastructure while maintaining agility in a rapidly evolving digital landscape. The POD 40c exemplifies HP's commitment to providing innovative and performance-driven data center solutions, positioning it as a transformative asset for businesses seeking to thrive in a data-driven world.