Data Analyzer Commands

display

display

The display command displays the contents of the capture file (.eve) to the screen or to standard out.

Format

display filename [-f] [-o opts] [-e e1 [e2]] [-l lcn#1 ...]

Description

The display command options have the following meanings:

-f

Follow the end of the file (i.e. wait and display data as

 

it arrives).

-o

Set the display options (see the options command for

 

details of option setting). Note the option settings

 

modified in this command change the default options

 

for the next display command.

-e

Specify event numbers to display. If <e1> is specified

 

alone, then only <e1> will be displayed. If <e1> and

 

<e2> are specified, then events in the range <e1> to

 

<e2> are displayed.

-l

Display only the events for the LCN numbers specified.

 

Up to 6 LCN numbers may be specified. Note the LCN

 

masking done here is post processing from the file, and

 

is different from the pre-processing done by the run

 

command.

-p

Specify level 2 or level 3 protocol for analysis and trace

 

display. See the protocol command for specific details

 

on format for option -p.

Chapter 3

27