Data Analyzer Commands

run

-p

Specify level 2 or level 3 protocol for analysis and trace

 

display. See the protocol command for specific details

 

on format for option -p.

Examples

To start the analyzer on ZLUs 19 and 20 use the command:

run 19

The command run 20 would have the same effect. In this example the default file name would be /var/opt/acc/log/anz_19.eve. If run 20 had been used the file name would have been /var/opt/acc/log/anz_20.eve, but the data captured would have been the same.

Display> run 19

Analyzer on ZLUs 19 and 20 started OK

To start the analyzer with LCN filtering for LCN numbers 120, 139, and

200 use the following command:

Display> run 19 -l 120 139 200

Analyzer on ZLUs 19 and 20 started OK