Network Configuration

Setting Up the Network Configuration File

NOTE

Setting Up the Network Configuration File

The first step is to configure the analyzer ports into the ttgen configuration file. A sample file is supplied with the product to illustrate how the configuration should be done. This file is called /opt/acc/cfg/x25an_sample.answ, or x25an_4ch_sample.answ. A full listing of these files is given at the end of this appendix. Some parts of these files are used below to illustrate the configuration process.

If the sample file is to be used as a test of the product, ensure that the multiplexer bus and slot numbers are changed in the file so that they correspond to the actual position of the multiplexer card.

Mux Firmware Download File

The Frame capture protocol used by the X.25 Protocol Analyzer is provided in all the downloadable files. The X.25 Protocol Analyzer may be used with any of these files.

The mux firmware download file is specified in the network configuration file in the card-type statement. For example:

z7340a 0 0:4 /opt/acc/z7340a/x25.zabs

Each multiplexer that is to run X.25 connections, or Data Analyzer ports, will need a card-type entry, such as z7340a. The bus and slot numbers must correspond to the physical position of the interface card. Refer to the ACC Installation and Configuration Guide for more information on determining the hardware location.

44