![Oil Level](/images/new-backgrounds/89383/89383103x1.webp)
LUBRICATION
Oil Level
Check the oil level in the engine when the machine is standing level and the engine is stopped.
Remove the dipstick, wipe it clean, and screw it back into place.
Take the dipstick out again and read the oil level. The oil level shall lie between the markings on the dipstick. If the level is approaching the “ADD” mark, fill the oil to the “FULL” mark on the dipstick. Never fill above the “FULL” mark.
The oil is filled through the hole for the dipstick. API class SF, SG, SH, SJ or higher must be used Synthetic oil SAE
The engine holds 1.5 quarts (1.4 liters) of oil excluding the filter; including the filter 1.6 quarts (1.5 liters).
Changing the Oil Filter
1.Drain the engine oil following the procedure described in Engine Oil/ Change Engine Oil section.
2.Remove the oil filter. If necessary, use a filter remover.
3.Wipe new, clean engine oil on the seal of the new filter.
4.Mount the filter by hand with + ¾ turn.
5.Run the engine warm, to check that there are no leaks around the oil filter seal.
Transmission
The transmission is maintenance free and there is no need for level checks or oil changes. If a leak occurs, replace the unit or contact your Husqvarna dealer.
English
Remove the dipstick
Dipstick markings
Kohler oil filter
Briggs & Stratton oil filter