Husqvarna 16C, 13C Checking the blades, Removing the BioClip plug, Rider 11 C, 13 C, 16 C, 16 AWD

Models: 11C 11R 16C 16CAWD 13C

1 44
Download 44 pages 525 b
Page 32
Image 32
Checking the blades

Maintenance

3Fit the front cover.

4Set the cutting height control to one of the positions 1-7

Checking the blades

To achieve the best mowing results it is important that the blades are undamaged and well-sharpened.

Check that the blades’ attachment screws are tight.

Rider 11 C, 13 C, 16 C, 16 AWD

Put the unit in the service position, see Service position for the cutting unit.

Rider 11 R

Lift up the cutting unit

Set the cutting height control in the highest position.

IMPORTANT INFORMATION

Replacing or sharpening the blades should be conducted by an authorised service workshop.

The blades should be balanced after sharpening.

Damaged blades should be replaced when hitting obstacles that result in a breakdown. Let the servicing dealer judge whether the blade can be repaired/ground or must be discarded.

WARNING! If the blades are cracked,

!whether caused by poor repair or other damage, they could break while being used. The risk increases if the blades are poorly balanced.

Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit with rear ejection, remove the BioClip plug located under the unit with three screws.

1Put the unit in the service position, see Service position for the cutting unit.

2Loosen the knob holding the BioClip-plug and remove the plug.

3Replace the unit in normal position. Fit the BioClip plug in the reverse order.

32 – English

Page 32
Image 32
Husqvarna 16C, 13C Checking the blades, Removing the BioClip plug, Rider 11 C, 13 C, 16 C, 16 AWD, Rider 11 R, Maintenance