Warning

: Do

not

replace

a nondefective FRU.

 

Reseat

the

keyboard

cables.

 

Replace

the

DC/DC card.

 

Replace

the

system board.

Auxiliary

Input

Devices:

The following auxiliary

input devices

are supported:

Numeric keypad

 

Mouse

(PS/2

compatible)

External

keyboard

(with keyboard/mouse cable)

If any of these devices do not work, reseat the cable connector and repeat the failing operation.

If the problem remains, replace the device, and then the system board.

Memory Checkout

DIMMs are available for increasing memory capacity.

DIMM

 

 

 

Displayed

Value

 

 

 

 

 

 

 

 

 

No

DIMM installed

 

32192

KB

 

 

 

 

 

 

 

 

 

 

 

16

MB

 

 

48576

KB

 

 

 

 

 

 

 

 

 

 

 

 

32

MB

 

 

64960

KB

 

 

 

 

 

 

 

 

 

 

 

 

64

MB

 

 

97728

KB

 

 

 

 

 

 

 

 

 

 

Memory errors

may

cause

error messages

to appear on

the

screen or

may

hang

the

operating

system.

Take the following procedure to isolate memory problems:

1.Turn off the computer and remove any installed DIMM from the slot.

2.Press and holdF1 theky; then turn on the

 

computer. Hold

theF1 key down until the

 

 

 

 

Easy-Setup menu appears.

 

 

 

 

 

 

 

 

3.

SelectTest

and

pressEnter .

 

 

 

 

 

 

 

 

4.

SelectMemory

 

 

and

pressEnter

to

run

the

memory

 

 

test for the base memory. If an error appears,

 

replace

the

system board.

 

 

 

 

 

 

5.

Turn off

the

computer

and

reinstall

the

DIMM;

then

 

turn on the computer. Verify

the

memory

size;

then

 

test the memory. If an error message appears,

 

replace

the

DIMM.

 

 

 

 

 

 

 

 

If a memory problem occur

intermittently,

perform

the loop

option

test. If

the

test

detects

an

error, it

prints an error

log on a printer connected to the parallel port. See

“Displaying

the

Error

Log”

on

page 35

for

more

 

information.

 

 

 

 

 

 

 

 

 

 

 

 

 

Flash

Memory

Update:

 

System setup programs and

 

 

diagnostic

tests

are stored in the flash memory. A flash

memory

update

is

required

when:

 

 

 

 

 

 

 

A

new

version

of

the system

program

is

installed.

12

Page 14
Image 14