Symptom / Error FRU / Action in Sequence
Power shuts down during
operation. 1. Go to “Power
Systems Checkout”
on page 13.
2. Battery pack
3. Remove the battery
pack and let it cool for
2 hours.
4. DC/DC card
5. System board
6. Check the power
outlet.
The system does not power
off.
(See “Reset Switch” on
page 7.)
1. Press the Reset
switch.
2. DC/DC card
3. System board
Other Symptoms
Note: If you cannot find a symptom or an error in this list
and the problem remains, see “Undetermined
Problems.”
Symptom / Error FRU / Action in Sequence
Errors occur only when the
port replicator is used. See “Port Replicator
Checkout” on page 18.
PC Card slot pin is
damaged. PC Card slots assembly.
Intermittent Problems
Intermittent system hang problems can be caused by a
variety of reasons that have nothing to do with a hardware
defect, such as: cosmic radiation, electrostatic discharge,
or software errors. FRU replacement should be
considered only when a recurring problem exists.
When analyzing the intermittent problem, do the following:
1. Run the advanced diagnostic test for the system
board in loop mode at least 10 times.
2. If no error is detected, do not replace any FRUs.
3. If any error is detected, replace the FRU shown by
the FRU code. Rerun the test to verify that no more
errors exist.
Undetermined Problems
You are here because the diagnostic tests did not identify
which adapter or device failed, installed devices are
incorrect, a short circuit is suspected, or the system is
inoperative. Follow these procedures to isolate the failing
FRU (do not isolate nondefective FRUs).
Verify that all attached devices are supported by the
computer.
32