IBM SC41-5420-04 manual Required Parameter Group, User profile, Remote IP address, Command string

Models: SC41-5420-04

1 116
Download 116 pages 15.73 Kb
Page 103
Image 103

3.

If any exception is encountered when calling the exit program, the REXEC server will not allow the operation and the message Exception encountered for REXEC exit program &1 in library &2 for exit point &3.is issued to the job log.

The following note applies to the TFTP server (application identifier 3):

1.For the TFTP server program, operation identifier 6 indicates the TFTP Read Request (RRQ) operation; operation code 7 indicates the TFTP Write Request (WRQ) operation.

Remote Execution Server Command Processing Selection Exit

Point

 

 

 

 

The REXEC server command processing selection exit program enables you to

 

select:

 

 

 

 

v Which command processor runs the command that the REXEC client user

 

provides

 

 

 

v Whether the REXEC server converts data between ASCII and EBCDIC (for

 

Qshell commands or spawn path names)

 

 

Required Parameter Group:

 

 

 

 

 

 

 

 

1

User profile

Input

Char(10)

 

 

2

Remote IP address

Input

Char(*)

 

3

Length of remote IP address

Input

Binary(4)

 

4

Command string

Input

Char(*)

 

5

Length of command string

Input

Binary(4)

 

6

Command processor identifier

Output

Binary(4)

 

7

Character conversion option

Output

Binary(4)

 

 

 

 

 

 

Exit Point Name: QIBM_QTMF_SVR_SELECT

 

 

 

 

Exit Point Format Name: RXCS0100

 

 

 

Note: Character data passes to the exit program in the coded character set

 

identifier (CCSID) of the job. If the job CCSID is 65535, the server uses the

 

default CCSID of the job.

 

 

 

Required Parameter Group

 

 

 

User profile

 

 

 

INPUT; CHAR(10) The user profile under which the requested operation is

 

run.

 

 

 

 

Remote IP address

 

 

 

INPUT; CHAR(*) The Internet Protocol (IP) address of the REXEC client

 

system. This string is in dotted decimal format, left justified.

 

Length of remote IP address

 

 

 

INPUT; BINARY(4) Indicates the length (in bytes) of the remote IP address.

 

Command string

 

 

 

INPUT; CHAR(*) The command to be run as specified by the REXEC client.

 

Length of command string

 

 

 

INPUT; BINARY(4) Indicates the length (in bytes) of the command string.

Appendix B. TCP/IP Application Exit Points and Programs 89

Page 103
Image 103
IBM SC41-5420-04 Required Parameter Group, User profile, Remote IP address, Length of remote IP address, Command string