Icom IC-M504 DSC Set mode, DMMSI code check See p, DAdd Individual ID/Group ID See pgs. 17

Models: IC-M504

1 80
Download 80 pages 19.82 Kb
Page 53
Image 53
■DSC Set mode

DSC Set mode

DMMSI code check (See p. 16)

DAdd Individual ID/Group ID (See pgs. 17, 19)

DDelete Individual ID/Group ID (See pgs. 18, 20)

DOffset time

This item sets the offset time from the UTC (Universal Time Coordinated) time.

qPush [MENU] to enter the DSC menu.

w Rotate [DIAL] to select “Set up,” and push [DIAL•ENTER].

--DSC Menu-- Select Item

POS Report Reply Polling Request Polling Reply Received Calls Distress Setting

˘Set up

eRotate [DIAL] to select “Offset Time,” push [DIAL•ENTER].

--DSC Menu--

Select Item

Add:INDV ID

Add:Group ID

DEL:INDV ID

DEL:Group ID

˘Offset Time

MMSI Check

DSC OPERATION 6

rSet the offset time from the UTC (Universal Time Coordi- nated) time by rotating [DIAL].

Push [16•9] or [CH/WX•DUAL•U/I/C] to move the cursor forward or backward, respectively.

Push [CLR] to cancel and return to the set up menu.

--DSC Menu--

Input Offset Time

6

00:00

 

<CLR˘Exit / ENT˘OK>

No offset time (default)

--DSC Menu--

Input Offset Time

+12:00

<CLR˘Exit / ENT˘OK>

+12 hours

tPush [DIAL•ENTER] to program and to return to the set up menu.

47

Page 53
Image 53
Icom IC-M504 DSC Set mode, DMMSI code check See p, DAdd Individual ID/Group ID See pgs. 17, DOffset time, Dsc Operation