■Automatic foghorn function

Automatic foghorn function

The automatic foghorn function sounds a horn repeatedly until the function is turned OFF. Four patterns are available for varying conditions.

OTHER FUNCTIONS 7

The foghorn outputs from the hailer speaker. To use this func- tion, the hailer speaker must be connected to the transceiver. See p. 58 for connection details.

TYPE

PATTERN

 

 

 

 

 

 

USAGE

 

 

 

 

5s± 1

 

 

 

 

 

 

 

UNDERWAY

One 5-second blasts every 120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor vessel underway and making way.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5s± 1

 

 

 

 

 

 

 

STOP

Two 5-second blasts (separated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor vessel underway but stopped (not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

by 2 seconds) every 120 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

making way).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2s

120s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

One 5-second blast followed by

 

 

5s± 1

 

 

 

 

 

 

Sailing vessel underway, fishing vessel

 

 

 

 

 

 

 

 

 

(underway or anchored), vessel not under

 

two 1-second blasts (each sepa-

 

 

 

 

 

 

 

1s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

command, a vessel restricted in her ability

rated by 2 seconds) every 120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to maneuver (underway or at anchor), or a

 

seconds.

 

 

 

 

 

2s

120s

 

 

 

 

 

 

 

 

 

 

 

 

vessel towing or pushing another ahead.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

One 5-second blast followed by

 

 

5s± 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

three 1-second blasts (each sep-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vessel under tow (manned).

arated by 2-seconds) every 120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

seconds.

 

 

 

 

 

 

2s

120s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The audio frequency of the foghorn is selectable. See p. 57 for details on selecting the audio frequency.