3.3.4 Verifying the Installation:

This section will guide you on how to verify if the I-7563 was properly installed. You will also need to determine the COM port assignment made by Windows for the USB to 3 Ports RS-485 Hub.

Note: Before you plug in the I-7563 for the first time, make sure that you do not attach any serial device first to the converter. You must only plug in the I-7560 itself.

To verify if the device is properly installed and determine the COM port assignment of the device:

1.Click Start _ __ _ Control Panel _ __ _ System. Inside System Properties, click on Device Manager. Double-click on Ports (COM & LPT1). You should see the I-7563USB-to-3 Ports RS485 Hub (COM3) device listing. This also means that Windows has assigned the device to COM3 port.

7000 Bus Converter User Manual (version 1.2,Feb/2003, 7PH-006-10) ---------------