Page 44
OTHER MENUFuncon Command Direcon Parameter Reply Control/Response contents *1
Screen Size (PC) WIDE WR 1-5 1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2 ○
Screen Size (AV) WIDE WR 1-5 1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot ○
Volume VOLM WR 0-31 0-31 ○
Mute MUTE WR 0-1 0-1 0: OFF, 1: ON -
Informaon Model INF1 R Value ●
Serial No. SRNO R Value
Bright VLMP WR 0-31 0-31 ○
Temperature Sensor DSTA R0Internal temperature normal ●
1Internal temperature abnormal (Standby mode)
2Internal temperature abnormal (Temperature is normal now, but it was
abnormal during operaon.)
3Internal temperature abnormal (Brightness of the backlight decreases.)
4Temperature sensor abnormal
Temperature Aquision ERRT R Value Temperature at temperature sensors 1 through 3 are returned in the fol-
lowing forms:
[Sensor 1], [Sensor 2], [Sensor 3]
Indicates a temperature sensor abnormality when “126” is returned.
○
Cause of Last Standby
Mode
STCA W 0 Inializaon ●
R0No detectable error has occurred
1Standby mode by POWER buon
2Main power o by the monitor power switch
3Standby mode by RS232C or LAN
4Waing mode by No Signal
6Standby mode by abnormal temperature
8Standby mode by SCHEDULE seng
20 Standby mode by OFF IF NO OPERATION seng
COMMANDS FOR SETTING THE GAMMA USER DATAFuncon Command Direcon Parameter Reply Control/Response contents *1
Red Gamma Data Transfer UGRW Waaxxxx ··· xxxxcc
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and
user data
○
Green Gamma Data Transfer UGGW W
Blue Gamma Data Transfer UGBW W
Red Gamma Data Read UGRR W 1-16 xxxx ··· xxxx
(xxxx: 32 pieces)
xxxx: 0000-1023
xxxx: User data of 32 pieces
Green Gamma Data Read UGGR W 1-16
Blue Gamma Data Read UGBR W 1-16
User Data Inalize UGRS W 0 Inialize the user data.
User Data Save UGSV W 0 Save the user data in the monitor.