Page 44
OTHER MENU
Funcon Command Direcon Parameter Reply Control/Response contents *1
Screen Size (PC) WIDE WR 1-5 1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
Screen Size (AV) WIDE WR 1-5 1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
Volume VOLM WR 0-31 0-31
Mute MUTE WR 0-1 0-1 0: OFF, 1: ON -
Informaon Model INF1 R Value
Serial No. SRNO R Value
Bright VLMP WR 0-31 0-31
Temperature Sensor DSTA R0Internal temperature normal
1Internal temperature abnormal (Standby mode)
2Internal temperature abnormal (Temperature is normal now, but it was
abnormal during operaon.)
3Internal temperature abnormal (Brightness of the backlight decreases.)
4Temperature sensor abnormal
Temperature Aquision ERRT R Value Temperature at temperature sensors 1 through 3 are returned in the fol-
lowing forms:
[Sensor 1], [Sensor 2], [Sensor 3]
Indicates a temperature sensor abnormality when “126” is returned.
Cause of Last Standby
Mode
STCA W 0 Inializaon ●
R0No detectable error has occurred
1Standby mode by POWER buon
2Main power o by the monitor power switch
3Standby mode by RS232C or LAN
4Waing mode by No Signal
6Standby mode by abnormal temperature
8Standby mode by SCHEDULE seng
20 Standby mode by OFF IF NO OPERATION seng
COMMANDS FOR SETTING THE GAMMA USER DATA
Funcon Command Direcon Parameter Reply Control/Response contents *1
Red Gamma Data Transfer UGRW Waaxxxx ··· xxxxcc
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and
user data
Green Gamma Data Transfer UGGW W
Blue Gamma Data Transfer UGBW W
Red Gamma Data Read UGRR W 1-16 xxxx ··· xxxx
(xxxx: 32 pieces)
xxxx: 0000-1023
xxxx: User data of 32 pieces
Green Gamma Data Read UGGR W 1-16
Blue Gamma Data Read UGBR W 1-16
User Data Inalize UGRS W 0 Inialize the user data.
User Data Save UGSV W 0 Save the user data in the monitor.