27
9. Install the battery box(es) into the wheelchair. Refer
to INSTALLING/REMOVING BATTERY BOX(ES) in
the PROCEDURE 10 - FWD MODELS or PROCE-
DURE 11 - RWD MODELS of this manual.
NOTE: New Battery(ies) MUST be fully charged BEFORE
using, otherwise the life of the battery(ies) will be reduced.
10. If necessary, charge the battery(ies). Refer to
CHARGING BATTERIES in the PROCEDURE 10 -
FWD MODELS or PROCEDURE 11 - RWD MOD-
ELS of this manual.
DETAIL B
NOTE: Battery clamps exploded away for clarification purposes only.
Mounting Plate
FIGURE 6 - CONNECTING BATTERY CABLES - BATTER Y CLAMP METHOD
CONNECTING BATTERY CABLE(S) TO BATTERY(IES) TERMINAL(S)/POST(S)
CONNECTING BATTERY CABLE(S) TO BATTERY(IES) TERMINAL(S)/POST(S)
Hex Screw
Negative (-) BLACK
Battery Cable
Positive (+) RED
Battery Cable
Battery Clamp
POSITIVE (+) Battery Terminal/
Post and Battery Clamp NEGATIVE (-) Battery Terminal/
Post and Battery Clamp
Positive (+) RED
Battery Cable
Negative (-) BLACK
Battery Cable
Group 22NF Battery
POSITIVE (+) Battery
Terminal/Post
Mounting Plate
Group 22NF Battery NEGATIVE (-) Battery Terminal/Post
TOP VIEW
EXPLODED
VIEW
RED Battery Clamp Cover
NEGATIVE (-) Battery
Terminal/Post
Tie-Wrap
BLACK Battery Clamp Cover
Group 22NF Battery
Tie-Wrap
POSITIVE (+) Battery
Terminal/Post
PROCEDURE 9BATTERIES
B
A
T
T
E
R
I
E
S
DETAIL "A"
Fuse
Box
Fuse Box placement
when box top
is installed