Ironman Fitness V2 instruction manual To Delete A Detector, Walk Test Mode

Models: V2

1 56
Download 56 pages 1.36 Kb
Page 43
Image 43
TO DELETE A DETECTOR

NOTE: If you attempt to learn in a device that is already learnt it will be deleted and added to

the new zone eg: If a WPIR is in zone 3 and you wish to move it to zone 5 relearning in zone 5 will delete it from zone 3 and add it to zone 5.

TO DELETE A DETECTOR

1.

2.

Set the dipswitch to on for the zone you wish to delete. I.e. if you wish to delete the sensor currently programmed into Zone 1, set dipswitch 1 to on as shown.

DELETE

3.

D

Press the DELETE button.

The unit will beep once to confirm the zone was deleted.

Walk test mode should be used when testing the system or after a new detector has been learnt into the system.

Beeps once on entering this mode

The unit will beep out the zone number of any device triggered

The unit will not beep out if the signal strength is not good enough Any dipswitch, or remote pressed, will exit walk test mode.

The detectors being tested should also be set into Walk Test Mode, see page 22.

WALK TEST MODE

1.

2.

3.

Set dipswitches 1 and 3 to on.

Walk Test mode is now active.

￿Press Button 2 to exit Walk Test mode

43

Page 43
Image 43
Ironman Fitness V2 instruction manual To Delete A Detector, Walk Test Mode