Jackson 200B, 200S Specification Information, Operating Capacities, Performance/Capabilities

Models: 200B 200LT 200 200S

1 57
Download 57 pages 11.25 Kb
Page 7
Image 7
SECTION 1: SPECIFICATION INFORMATION

SECTION 1: SPECIFICATION INFORMATION

OPERATING CAPACITIES

 

 

 

 

 

 

 

 

 

PERFORMANCE/CAPABILITIES

 

ELECTRICAL REQUIREMENTS

 

 

 

 

 

 

 

 

OPERATING CAPACITY (RACKS/HOUR)

 

WASH PUMP MOTOR HP

 

 

 

1

RACKS PER HOUR

57

 

 

 

 

 

 

 

 

 

 

 

DISHES PER HOUR

1425

NOTE: Typical Electrical Circuit is based upon (1) 125% of

GLASSES PER HOUR

1425

the full amperage load of the machine and (2) typical fixed-

 

 

trip circuit breaker sizes as listed in the NEC 2002 Edition.

OPERATING CYCLE (SECONDS)

 

Local codes may require more stringent protection than

 

 

what is displayed here. Always verify with your electrical

WASH TIME

45

service contractor that your circuit protection is adequate

RINSE TIME

11

and meets all applicable national and local codes. These

TOTAL CYCLE

58

numbers are provided in this manual simply for reference

TANK CAPACITY (GALLONS)

 

and may change without notice at any given time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RINSE

 

 

TYPICAL

WASH TANK (MINIMUM)

8.0

MODEL

VOLTS PH

HZ

HEATER

TOTAL

ELECTRICAL

BOOSTER TANK

3.0

RATINGS

AMPS

CIRCUIT

200B

208

1

60

12KW@230

72 A

90 AMP

 

 

WASH PUMP CAPACITY

 

200B

230

1

60

12KW@230

79 A

100 AMP

 

200B

208

3

60

12KW@230

40 A

50 AMP

 

 

GALLONS PER MINUTE

150

200B

230

3

60

12KW@230

44 A

60 AMP

200B

460

3

60

12KW@230

22 A

25 AMP

TEMPERATURES

 

200B

208

1

60

14KW@230

79 A

100 AMP

 

 

200B

230

1

60

14KW@230

87 A

110 AMP

WASH---°F (MINIMUM)

150

200B

208

3

60

14KW@230

44 A

60 AMP

RINSE---°F (MINIMUM)

180

200B

230

3

60

14KW@230

49 A

70 AMP

WASH---°F (MINIMUM) (200 LT)

130

200B

460

3

60

14KW@230

25 A

36 AMP

 

 

 

 

 

 

 

 

RINSE---°F (MINIMUM) (200 LT)

130

200

208

1

60

N/A

29 A

40 AMP

 

 

NOTE: Always refer to the machine data plate for specific

200

230

1

60

N/A

31 A

40 AMP

200

208

3

60

N/A

15 A

20 AMP

electrical and water requirements. The material provided on

200

230

3

60

N/A

16 A

20 AMP

this page is for reference only and may be

subject to

200

460

3

60

N/A

8

A

15 AMP

change without notice.

 

200/LT

208

1

60

N/A

29 A

40 AMP

 

 

STEAM REQUIREMENTS

 

200/LT

230

1

60

N/A

31 A

40 AMP

 

200/LT

208

3

60

N/A

15 A

20 AMP

COIL SIZE

3/4”

200/LT

230

3

60

N/A

16 A

20 AMP

200/LT

460

3

60

N/A

8

A

15 AMP

STEAM FLOW PRESSURE (P.S.I.)

10-20

 

 

 

 

 

 

 

 

CONSUMPTION @ 15 P.S.I. (LBS/HR)

45

200S

208

1

60

N/A

7

A

15 AMP

 

 

WATER REQUIREMENTS (MINIMUM)

 

200S

230

1

60

N/A

7

A

15 AMP

 

200S

208

3

60

N/A

4

A

15 AMP

 

 

INLET TEMPERATURE (200)

180°F

200S

230

3

60

N/A

4

A

15 AMP

200S

460

3

60

N/A

4

A

15 AMP

INLET TEMPERATURE (200B)(40° Rise)

140°F

 

 

 

 

 

 

 

 

INLET TEMPERATURE (200B)(70° Rise)

110°F

 

 

 

 

 

 

 

 

INLET TEMPERATURE (200LT)

140°F

 

 

 

 

 

 

 

 

INLET TEMPERATURE (200S)

110°F

 

 

 

 

 

 

 

 

GALLONS PER HOUR

52.2

 

 

 

 

 

 

 

 

GALLONS PER RACK

0.92

 

 

 

 

 

 

 

 

WATER LINE SIZE NPT

3/4”

 

 

 

 

 

 

 

 

DRAIN LINE SIZE NPT

1 1/2”

 

 

 

 

 

 

 

 

FLOW PRESSURE P.S.I. (Optimum)

20A5

 

 

 

 

 

 

 

 

MINIMUM CHLORINE REQUIRED (PPM)(200LT)

50

 

 

 

 

 

 

 

 

200 Series Technical Manual

7610-100-45-00 Rev. E (02/10/2006)

2

Page 7
Image 7
Jackson 200B, 200S Specification Information, Operating Capacities, Performance/Capabilities, Electrical Requirements