Jackson AJ-44 Specification Information, Operating Characteristics, Racks Per Hour, given time

Models: AJ-44

1 68
Download 68 pages 34.22 Kb
Page 10
Image 10
SECTION 1: SPECIFICATION INFORMATION
110-140°F
160°F
180°F
110-140°F
140°F
140°F
20±5
3.9
3.9
50
AJ-44C Series Technical Manual 7610-001-76-22
Issued: 03-21-2006 Revised: N/A
2

SECTION 1: SPECIFICATION INFORMATION

OPERATING CHARACTERISTICS

RACKS PER HOUR:

 

STEAM COIL TANK HEAT (CS/CSL MODELS ONLY):

AJ-44-66-80CE/CS/CGP

248

STEAM INLET PRESSURE (PSIG)

10-20

AJ-44-66-80CEL/CSL

234

STEAM CONNECTION NPT

3/4”

DISHES OR GLASSES PER HOUR:

 

CONSUMPTION @ 15 PSIG (lbs/hr):

 

 

AJ-44-66-80CS/CSL

60

AJ-44-66-80CE/CS/CGP

6200

 

 

AJ-44-66-80CEL/CSL

5850

MOTOR ELECTRICAL CHARACTERISTICS:

 

PREWASH TANK CAPACITY (GALLONS):

 

DRIVE MOTOR HP

1/4

 

WASH MOTOR HP

2

AJ-66CE/CEL/CS/CSL/CGP

16

POWER RINSE MOTOR HP

2

AJ-80CE/CEL/CS/CSL/CGP

16

PREWASH MOTOR HP:

 

WASH TANK CAPACITY (GALLONS):

 

AJ-66 MODELS

1

 

AJ-80 MODELS

2

AJ-44-66-80CE/CS/CGP

15.4

NOTE: Typical Electrical Circuit is based upon (1) 125% of

 

 

PREWASH PUMP CAPACITY (GPM):

 

the full amperage load of the machine and (2) typical

AJ-66CE/CEL/CS/CSL/CGP

120

fixed-trip circuit breaker sizes as listed in the NEC 2002

AJ-80CE/CEL/CS/CSL/CGP

270

Edition. Local codes may require more stringent protec-

 

 

tion than what is displayed here. Always verify with your

WASH PUMP CAPACITY

 

electrical service contractor that your circuit protection is

GALLONS PER MINUTE (ALL MODELS):

270

adequate and meets all applicable national and local

 

 

codes. These numbers are provided in this manual sim-

VENTING REQUIREMENTS (CFM)(100% CAP.):

 

ply for reference and may change without notice at any

INPUT END

200

given time.

 

OUTPUT END

400

 

 

TOTAL

600

 

 

CONVEYOR SPEED (FPM):

 

 

 

AJ-44-66-80CE/CS/CGP MACHINES

6.9

 

 

AJ-44-66-80CEL/CSL MACHINES

6.5

 

 

GALLONS PER RACK:

 

 

 

AJ-44-66-80CE/CS/CGP MACHINES

.94

 

 

AJ-44-66-80CEL/CSL MACHINES

1.00

 

 

WATER TEMPERATURES:

AJ-44-66-80CE/CS/CGP MODELS:

PREWASH (RECOMMENDED)

WASH (MINIMUM)

RINSE (MINIMUM)

AJ-44-66-80CEL/CSL MODELS:

PREWASH (RECOMMENDED)

WASH (MINIMUM)

RINSE (MINIMUM)

FLOW PRESSURE (PSI)

FLOWRATE (GPM):

AJ-44-66-80CE/CS/CGP

AJ-44-66-80CEL/CSL

MINIMUM CHLORINE (PPM)

AJ-44-66-80CEL/CSL MODELS ONLY:

Page 10
Image 10
Jackson AJ-44 Specification Information, Operating Characteristics, Racks Per Hour, Dishes Or Glasses Per Hour, given time