Jackson AJ-44 Information, Specification, Right to Left, Left Side, Front View, Right Side

Models: AJ-44

1 68
Download 68 pages 34.22 Kb
Page 16
Image 16
Recommended Table Fabrication

 

Issued: 03-

AJ-44C Series

8

21-2006 Revised: 09-29-2007

Technical Manual 7610-001-76

 

 

-22

Right to Left

 

 

 

Recommended Table Fabrication

 

Note: Tub Will Accept

 

 

 

 

 

 

 

 

 

 

Rack Rail

 

 

 

a Table Flange

 

 

 

Legend to Drawing

 

 

 

 

 

 

 

 

 

 

 

Table

 

Up to 24 7/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(632 mm)

 

 

 

A - Machine water inlet 3/4" NPT, 180°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hi-temp,140°F Low-temp minimum

 

 

 

 

 

 

 

 

 

Use Silicone Sealer

3/4" (19 mm)

 

 

 

B - Electrical connection

 

 

 

 

 

Rack Rail Height

 

 

 

 

 

 

 

 

 

 

 

 

Between Table and

Table Turndown

21" (533 mm)

 

 

C - Drain connection 1-1/2" NPT

 

 

 

 

 

Tub

 

 

 

 

 

 

Above Dishtable

 

Lip of Machine to

 

 

D - Vent collar - Optional

 

 

 

 

 

Flange 3/4" Max

 

 

 

 

 

1/4" (6mm) - 5/16" (8mm)

 

Prevent Leakage

 

 

 

 

E - Vent cowl standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F - 3/4" NPT 180°F Water Inlet for wash tank

 

 

 

30 [763mm]

 

 

 

 

 

 

 

fill, final rinse, & tank heating. From gas

 

 

 

 

14 [357mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

booster heater. Interconnecting hose

 

 

 

 

 

 

11

[35mm]

741 [185mm]

 

4 1/2 [114mm]

 

 

 

provided by manufacturer.

 

 

 

 

 

 

 

 

6 [152mm]

 

 

 

 

 

G - 3/4" NPT 140°F Water inlet for

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

834 [222mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

gas booster heater.

 

113

 

 

 

 

 

 

 

 

 

 

 

 

 

H - 3/4" NPT 180°F Water Outlet

[298mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection to line on dishmachine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection hose provided by

 

 

 

 

 

 

 

 

 

 

 

A

 

21 [533mm]

 

 

manufacturer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J - 3/4" NPT Gas Connection

 

 

 

 

 

 

 

 

 

 

 

B

 

25 [635mm]

K - 4" OD Vent pipe connection. Flue to

 

143 [375mm]

 

 

 

 

 

 

 

 

 

 

be installed to meet local codes by

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

203 [527mm]

 

 

 

 

 

K

 

 

 

 

 

 

installing contractor.

 

 

 

 

 

H

G

J

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

44 [1118mm]

8 [203mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: All vertical dimensions are +/- 1/2" from

 

4" (102 mm) wide x 16" (406 mm)

 

Table to Table

Floor Sink Or Drain

 

 

floor due to adjustable bullet feet.

 

 

 

 

long cutout in Vent Cowl/Splash

 

52 [1321mm]

 

 

 

 

 

 

 

With 3" (76 mm)

 

 

 

 

 

 

 

 

Shield. Shipped with Cover Plate.

 

60 [1524mm]

 

 

84 [2134mm]

 

 

 

 

 

 

Minimum Drain Line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With Doors Open

 

 

 

 

 

 

 

 

 

 

 

 

Overall

1821 [467mm]

25 [635mm]

 

 

 

 

751

[1919mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

41 [1042mm]

 

 

21 [533mm]

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

8 [206mm] B

 

 

6621 [1692mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 [102mm]

 

A

B

12 [307mm]

 

 

 

 

 

 

 

 

 

1 [25mm]

 

 

6221 [1590mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 [178mm]

661

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

[1684mm]

 

 

 

 

1

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

604 [1530mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

25 [635mm]

 

 

 

 

 

 

 

314 [794mm]

 

 

 

 

 

 

Dish Clearance

 

 

 

21 [15mm]

 

 

 

261

[672mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

36 [914mm]

 

 

 

 

 

 

 

 

Rear of

 

 

 

 

 

 

 

16 [407mm]

 

 

 

 

 

Machine

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive

 

 

H

G

 

 

 

 

 

 

 

34 [864mm]

 

 

 

 

Unit

 

 

J

 

 

Drive

C

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

61

[163mm]

 

 

 

 

721 [191mm]

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29 [737mm]

 

7 [178mm]

6 [152mm]

C

 

 

 

 

 

 

 

 

 

 

 

81

[218mm]

 

 

 

 

 

 

 

 

 

 

 

 

10 [254mm]

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left Side

Front View

Right Side

AJ-44 GAS - RIGHT TO

SECTION 1: SPECIFICATION

LEFT

INFORMATION

Page 16
Image 16
Jackson AJ-44 Information, Specification, Right to Left, Left Side, Front View, Right Side, Recommended Table Fabrication