SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS (CONTINUED)
The exhaust system must be sized to handle this volume for the dishmachine to operate as it was designed to.
ELECTRIC HEAT: The thermostats for the machines covered in this manual are factory set. They should not be adjusted except by an authorized service agent.
CHEMICAL FEEDER EQUIPMENT: The
Detergent may be introduced into the unit through the removal of the bulkhead plug in the rear of the tub and replacing it with the third party detergent injection fitting. Remove the bulkhead plug in the side of the tub to install the detergent concentration probe.
For more information concerning detergent concerns, please refer to
Brass Plug the page entitled “Detergent Control”.
Detergent Connection Point
(Machine rear view)
The 1/8” brass plugs on the incoming plumbing rinse injector may be removed to install sanitizer and rinse aid injection fittings.
Brass Plugs
Back of Control Box
All wires for the chemical injectors should be routed through one of the extra openings in the back of the control box.
Terminals in the control box marked “CVS” provide a constant voltage signal whenever the drive motor is operating.
Terminals in the control box marked “DET” provide a voltage signal whenever the wash motor is operating.
Aid Connection Points
Issued:
32