Jackson AJ-44 Right to Left, Recommended Table Fabrication, Drive, Unit, Left Side, Front View

Models: AJ-44

1 68
Download 68 pages 34.22 Kb
Page 20
Image 20
Right to Left

 

Issued: 03-

AJ-44C Series

12

21-2006 Revised: 09-29-2007

Technical Manual 7610-001-76

 

 

-22

Right to Left

Recommended Table Fabrication

 

 

Note: Tub Will Accept

 

 

 

 

Rack Rail

 

 

 

 

 

a Table Flange

 

 

Legend

 

 

 

 

 

 

 

Table

 

 

Up to 24 7/8"

 

 

 

 

 

 

 

 

 

 

 

(632 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A - Machine water inlet 3/4" NPT, 180°F

 

 

 

 

 

Use Silicone Sealer

 

 

 

 

Hi-temp,140°F Low-temp minimum

 

 

 

 

 

3/4" (19 mm)

 

 

 

 

 

 

 

Between Table and

 

 

B - Electrical connection

 

 

Rack Rail Height

 

 

Table Turndown

21" (533 mm)

 

 

 

Tub

Lip of Machine to

 

 

C - Drain connection 1-1/2" NPT

 

Above Dishtable

Prevent Leakage

 

Flange 3/4" Max

 

 

D - Vent collar - Optional

 

1/4" (6mm) - 5/16" (8mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E - Vent cowl standard

 

 

 

 

 

 

 

 

 

 

 

 

 

F - Prewash water inlet 3/4" NPT

 

 

 

 

 

 

 

 

 

 

 

 

110°F-140°F

 

 

 

 

 

4 1/2 [114mm]

 

 

 

 

1634 [425mm]

G - Cold water thermostat plumbing

 

 

 

 

 

 

 

 

connection 3/4" NPT - Optional

 

 

 

 

 

 

 

 

 

 

161

[415mm]

 

 

 

 

 

A

 

 

F

 

 

 

21 [533mm]

4

F

 

 

 

 

 

 

 

 

 

 

 

Note: All vertical dimensions are +/- 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 [635mm]

 

from floor due to adjustable bullet feet.

 

 

B

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prewash Plan View Section

 

 

 

 

 

 

 

 

 

 

 

81

[210mm]

with Cold Water Thermostat

 

4" (102 mm) wide x 16" (406 mm)

 

44 [1121mm]

 

22 [559mm]

 

 

4

 

 

 

 

 

 

 

 

Floor Sink Or Drain

 

 

 

long cutout in Vent Cowl/Splash

 

Base Unit

 

 

Prewash

 

 

 

 

 

 

66 [1679mm]

 

 

 

 

With 3" (76 mm)

 

 

 

Shield. Shipped with Cover Plate.

 

Table to Table

 

 

 

 

 

 

 

 

Minimum Drain Line

 

 

 

 

 

 

 

74 [1883mm]

 

 

 

 

 

84 [2134mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

82 [2086mm] Overall

 

 

 

 

 

 

 

With Doors Open

 

7521 [1919mm]

42 [1067mm]

 

 

24 [610mm]

25 [635mm]

 

661

[1692mm]

A

 

 

 

2

 

 

 

 

41 [1041mm]

 

 

2321 [599mm]

21 [533mm]

 

1 [25mm]

F

 

8 [203mm]

B

 

12 [307mm]

3 [79mm]

G

 

 

 

A

 

 

 

B

 

4 [102mm]

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

7 [178mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

6641 [1684mm]

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

1

[1590mm]

 

 

 

 

 

 

25 [635mm]

 

 

 

 

622

 

 

 

 

 

 

Dish Clearance

 

21 [15mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

601

[1530mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

Rear of

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine

Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive

 

 

24 [610mm]

 

 

 

34 [864mm]

 

 

 

Unit

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

6 [152mm]

 

29 [737mm]

 

6 [152mm]

1041 [260mm]

 

C

821 [217mm]

 

 

 

 

 

10 [254mm]

 

 

 

 

 

 

 

Left Side

Front View

Right Side

SECTION 1: SPECIFICATION INFORMATION AJ-66 ELECTRIC - RIGHT TO LEFT

Page 20
Image 20