Issued: 03-

AJ-44C Series

13

21-2006 Revised: 09-29-2007

Technical Manual 7610-001-76

 

 

-22

Left to Right

 

Recommended Table Fabrication

Note: Tub Will Accept

 

 

 

 

 

 

163 [425mm]

 

 

 

 

 

161

[415mm]

 

Legend

 

 

 

 

 

 

 

 

 

a Table Flange

 

 

4

 

 

 

 

 

Rack Rail

 

 

 

 

4

 

 

 

L

A - Machine water inlet 3/4" NPT, 180°F

 

 

 

 

Up to 24 7/8"

 

 

 

 

 

 

 

 

 

 

 

Table

 

 

 

 

 

 

 

 

Hi-temp,140°F Low-temp minimum

 

 

 

 

 

 

(632 mm)

 

 

 

 

 

 

M

B - Electrical connection

 

 

 

 

 

Use Silicone Sealer

 

 

 

 

 

 

 

 

 

C - Drain connection 1-1/2" NPT

 

 

 

 

 

3/4" (19 mm)

 

 

 

 

Prewash Plan View Section

 

 

 

 

 

Between Table and

 

 

 

 

D - Vent collar - Optional

 

 

 

 

 

 

 

 

 

 

Rack Rail Height

 

Table Turndown

 

21" (533 mm)

 

 

with Cold Water Thermostat

 

 

Lip of Machine to

 

 

 

E - Vent cowl standard

 

 

Tub

 

 

 

 

 

 

Above Dishtable

Prevent Leakage

Flange 3/4" Max

 

 

 

 

 

 

 

F - 3/4" NPT 180°F Water Inlet for wash tank

1/4" (6mm) - 5/16" (8mm)

 

 

 

30 [763mm]

 

 

 

 

 

 

 

 

fill, final rinse, & tank heating. From gas

 

 

 

 

 

 

1441 [363mm]

 

 

 

 

 

 

 

 

71

[185mm]

3

 

booster heater. Interconnecting hose

 

 

 

 

 

 

6 [154mm]

84 [222mm]

provided by manufacturer.

 

 

 

14 [355mm]

 

 

141 [35mm]

4

 

 

 

1134 [298mm]

G - 3/4" NPT 140°F Water inlet for

 

 

 

 

Minimum

 

 

 

 

 

 

 

 

143 [375mm]

gas booster heater.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

H - 3/4" NPT 180°F Water Outlet

 

 

 

 

 

L

 

 

 

 

 

 

 

 

2034 [527mm]

connection to line on dishmachine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection hose provided by

 

 

21 [533mm]

 

 

 

 

F

 

 

 

 

 

 

manufacturer.

 

 

 

 

8 [203mm]

 

 

 

 

 

 

 

 

J - 3/4" NPT Gas Connection

 

25 [635mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K - 4" OD Vent pipe connection. Flue to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be installed to meet local codes by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

installing contractor.

 

 

 

 

 

Scrap

 

 

 

 

H

G

J

K

 

L - Prewash water inlet 3/4" NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110°F-140°F

 

 

 

 

Trough

22 [559mm]

 

44 [1121mm]

 

Floor Sink Or Drain

 

 

M - Cold water thermostat plumbing

 

4" (102 mm) wide x 16" (406 mm)

 

 

With 3" (76 mm)

 

 

 

Prewash

 

Base Unit

 

 

 

connection 3/4" NPT - Optional

 

long cutout in Vent Cowl/Splash

66 [1679mm] Table to Table

 

Minimum Drain Line

 

 

 

 

 

 

Shield. Shipped with Cover Plate.

74 [1883mm]

 

 

 

 

 

 

 

Note: All vertical dimensions are +/- 1/2" from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

floor due to adjustable bullet feet.

 

41 [1040mm]

 

 

82 [2086mm] Overall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

231

[598mm]

 

 

 

 

 

 

 

 

 

25 [635mm]

 

41

[105mm]

 

 

2

 

 

 

 

 

18 [457mm]

 

 

 

 

 

 

24 [609mm]

 

 

 

 

 

 

 

21 [533mm]

 

4

L

M

 

 

 

 

 

8 [206mm]

 

 

 

 

A

 

4 [102mm]

 

 

 

B

 

 

 

 

12 [307mm]

 

 

 

 

 

L

A

 

 

B

 

 

 

 

 

 

 

 

21 [61mm]

 

 

 

 

 

 

1 [25mm]

 

 

751

[1919mm]

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

7 [178mm]

 

 

 

 

 

A

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

3 [79mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

311 [795mm]

 

 

 

 

 

84 [2134mm]

 

 

1

[1530mm]

 

 

 

 

 

 

 

 

 

25 [635mm]

 

 

604

 

 

 

 

 

 

4

 

 

 

 

With Doors Open

 

 

 

 

10" High

 

 

 

 

E

2621 [673mm]

 

 

 

 

Dish Clearance

1 [15mm]

 

 

 

 

Table

 

 

 

 

36 [914mm]

 

 

 

 

 

2

 

 

 

 

Backsplash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14 [356mm]

 

6 [152mm]

 

 

 

 

 

 

Rear of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

 

 

 

 

 

 

 

Machine

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive

 

 

Scrap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34 [864mm]

 

 

 

 

Trough

Drive

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

 

 

 

H

G

J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

C

 

 

 

K

 

 

 

 

 

 

 

 

 

 

 

 

 

27 [687mm]

 

 

 

 

 

 

 

 

 

 

6 [152mm]

 

 

 

 

 

6 [152mm]

 

61 [165mm]

 

 

 

C

 

 

 

 

29 [737mm]

 

10 [254mm]

 

 

 

 

 

81

[217mm]

 

Left Side

 

 

 

 

Front View

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

Right Side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECTION 1: SPECIFICATION INFORMATION AJ-66 GAS - LEFT TO RIGHT

Page 21
Image 21
Jackson AJ-44 technical manual Specification Information AJ-66 GAS Left to Right