JBL 260 user manual DriveRack, Section, INS A COMP - o+

Models: 260

1 84
Download 84 pages 37.71 Kb
Page 55
Image 55
INS A COMP - o+

 

 

 

 

Section 5

DriveRack

®

 

 

 

 

Utilities/Meters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.2.1 - Meters

 

To meter various aspects of the 260, press and hold the UTILITY button until the display enters the Metering section.

Use the PREV PG or NEXT PG button to move to the page that appears as follows:

INS A COMP - o+

1

B

-30-20 0 +20

 

INS

A

 

2

 

 

B

 

This page meters the gain reduction of any Dynamic block configured in the Insert 1 or Insert 2 block.

Use the PREV PG or NEXT PG button to move to the page that appears as follows:

-30-20 0 +20

1 LIM - 0+

2 LIM - 0+

3 LIM - 0+

This page meters the gain reduction being applied by the Dynamics modules on outputs 1-3. Pressing the NEXT PG button displays outputs 4-6.

Use the PREV PG or NEXT PG button to move to the page that appears as follows:

Zone Controllers

Panel 1

Panel 2

Panel 3

This (as well as the next) page shows any activity (such as level changes and program changes) being made by any connected ZC wall panels. Use the PREV PG or NEXT PG button to move to the page that appears as follows:

Output Trims

 

 

 

Trim

0.0

Net

0.0

dB

 

1

 

Trim

0.0

Net

0.0

dB

 

2

 

Trim

0.0

Net

0.0

dB

 

3

 

 

 

 

 

 

 

This (as well as the next) page displays the Trim and Net (Crossover gains + ZC gains) levels within the output section.

DriveRack® User Manual

 

47

 

 