Johnson Controls TM9V MP installation manual Installation Manual, List Of Sections, UIM-B-0509

Models: TM9V MP

1 38
Download 38 pages 36.38 Kb
Page 1
Image 1
INSTALLATION MANUAL

INSTALLATION MANUAL

RESIDENTIAL GAS FURNACE MODELS TM9V*MP

(96% AFUE Two Stage Variable Speed Multi-position)

EFFICIENCY

RATING

CERTIFIED

ISO 9001

Certified Quality

Management System

LIST OF SECTIONS

SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 GAS PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

CONDENSATE PIPING AND FURNACE

VENTING CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

COMBUSTION AIR and VENT SYSTEM . . . . . . . . . . . . . . . . . . . . 22 START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . 29 SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 REPLACEMENT PART CONTACT INFORMATION . . . . . . . . . . . . 36 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

LIST OF FIGURES

Duct Attachment

. 5

Thermostat Chart - Two Stage HP with Two Stage

 

Vertical Applications

. 5

Variable Speed Furnace (Hot Heat Pump or Conventional)

15

Coil Flange

. 5

Typical. Condensate drain, vertical installation

16

Horizontal Right Application

. 6

Typical. Combustion Pipe Drain Tee

17

Horizontal Left Application

. 6

Upflow Configuration

18

PC Series Upflow Coil Installation

. 6

Downflow Configuration

19

Horizontal Left or Right application (Right Shown)

. 6

Horizontal Left Configuration

20

Combustible Floor Base Accessory

. 7

Horizontal Right Configuration

21

Horizontal Application

. 7

Dimensions

22

Typical Attic Installation

. 7

Home Layout

24

Typical Suspended Furnace / Crawl Space Installation

. 7

Termination Configuration - 1 Pipe

25

Dimensions

. 8

Termination Configuration - 2 Pipe

25

Side Return Cutout Markings

. 8

Termination Configuration - 2 Pipe Basement

25

Gas Valve

. 9

Double Horizontal Combustion Air Intake and Vent Termination . . .

25

Upflow/Downflow Gas Piping

. 9

Double Vertical Combustion Air Intake and Vent Termination

25

Horizontal Gas Piping

. 9

Direct Vent Air Intake Connection and Vent Connection

26

Electrical Wiring

11

Combustion Airflow Path Through The Furnace Casing

26

Thermostat Chart - Single Stage Air Conditioners

 

Outside and Ambient Combustion Air

27

with Two Stage Variable Speed Furnaces

12

Attic and Crawl Space Combustion Air Termination

28

Thermostat Chart - Single Stage Heat Pump with Two Stage

 

Gas Valve

31

Variable Speed Furnace (Hot Heat Pump or Conventional)

13

Reading Gas Pressure

31

Thermostat Chart - Two Stage AC with

 

Furnace Control Board

32

Two Stage Variable Speed Furnace

14

Furnace Control Event Schedule

35

 

 

Wiring Diagram

37

LIST OF TABLES

Unit Clearances to Combustibles

. 4

Equivalent Length of Fittings

23

Coil Projection Dimensions - PC Series Coils

. 6

Combustion Air Intake and Vent Connection Size at

 

Cabinet and Duct Dimensions

. 8

Furnace (All Models)

23

Recommended Filter Sizes (High Velocity 600 FPM)

. 8

Estimated Free Area

26

Nominal Manifold Pressure - High Fire

10

Unconfined Space Minimum Area in Square Inch

27

Nominal Manifold Pressure - Low Fire

10

Free Area

27

Ratings & Physical / Electrical Data

11

Gas Rate (CU FT/HR) at Full Input

30

Maximum Equivalent Pipe Length

22

Inlet Gas Pressure Range

31

Elbow Dimensions

22

Nominal Manifold Pressure

31

These high efficiency, compact units employ induced combustion, reli- able hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applica- tions.

These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and oper- ation.

These units are Category IV listed and may not be common vented with another gas appliance as allowed by the National Fuel Gas Code.

SECTION I: SAFETY

This is a safety alert symbol. When you see this symbol on labels or in manuals, be alert to the potential for personal

injury.

Understand and pay particular attention to the signal words DANGER,

WARNING, or CAUTION.

DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury.

WARNING indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.

CAUTION indicates a potentially hazardous situation, which, if not avoided may result in minor or moderate injury. It is also used to alert against unsafe practices and hazards involving only property dam- age.

438335-UIM-B-0509
Page 1
Image 1
Johnson Controls TM9V MP installation manual Installation Manual, RESIDENTIAL GAS FURNACE MODELS TM9V*MP, List Of Sections