Johnson Controls TM9V MP Airflow, Downflow - Inducer Rotated, For Left Side Venting

Models: TM9V MP

1 38
Download 38 pages 36.38 Kb
Page 19
Image 19
AIRFLOW

Johnson Controls Unitary Products

19

FIGURE 25: Downflow Configuration

When drain hose routing changes are required, be sure to cap all un-used openings.

If rerouting hoses - excess length should be cut off so that no sagging loops will collect and hold condensate, which will cause the furnace to not operate.

AIRFLOW

AIRFLOW

 

1Move rain gutter hose

to this position.

2Move pressure switch hose to this position. NOTE: May require

the longer hose that is provided with wider cabinets.

3 Move rain gutter hose to this position.

4 Move condensate drain hose to this position (may exit either side of the

 

cabinet).

DOWNFLOW - INDUCER ROTATED

DOWNFLOW - INDUCER ROTATED

FOR LEFT SIDE VENTING

FOR RIGHT SIDE VENTING

438335-UIM-B-0509

Page 19
Image 19
Johnson Controls TM9V MP Airflow, Downflow - Inducer Rotated, For Left Side Venting, For Right Side Venting