Johnson Controls TM9V MP Horizontal - Right Inducer As Received, Inducer Rotated

Models: TM9V MP

1 38
Download 38 pages 36.38 Kb
Page 21
Image 21
HORIZONTAL - RIGHT

Johnson Controls

FIGURE 27: Horizontal

When drain hose routing changes are required, be sure to cap all un-used openings.

If rerouting hoses - excess length should be cut off so that no sagging loops will collect and hold condensate, which will cause the furnace to not operate.

Unitary Products

21

Right Configuration

1

HORIZONTAL - RIGHT

Move pressure

INDUCER ROTATED

switch hose to

 

this position.

 

AIRFLOW

INDUCER ROTATED 4 Move rain gutter hose to this position.

2 Change condensate drain connection to

the 90° fitting provided.

3 Move condensate drain hose to

this position.

1 Move pressure switch hose to this position.

HORIZONTAL - RIGHT

INDUCER AS RECEIVED

2

Change condensate drain

 

 

connection to the 90°

3

Move condensate

fitting provided

drain hose to this position

 

AIRFLOW

4

Move rain gutter hose to this position

438335-UIM-B-0509

Page 21
Image 21
Johnson Controls TM9V MP installation manual Horizontal - Right Inducer As Received, Inducer Rotated