Jotul GF 100 DV II, GF 200 DV II Optional Blower #, Installation, Connect The Gas Supply To The

Models: GF 100 DV II, GF 200 DV II

1 32
Download 32 pages 63.91 Kb
Page 24
Image 24
Optional Blower # 155631

GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

Optional Blower # 155631

CONNECT THE GAS SUPPLY TO THE

STOVE BEFORE INSTALLING THIS

BLOWER. USE A 90° ELBOW OFF THE

GAS VALVE TO CREATE ADEQUATE

GAS LINE CLEARANCE.

„ THIS BLOWER MUST BE

ELECTRICALLY GROUNDED IN

ACCORDANCE WITH LOCAL CODES

Contents

1.Blower

2.Snapstat Wire Harness

3.Control Box

4.Snapstat Bracket

5.Rheostat Knob

6.Snapstat

7.Mounting Bracket (GF100 DV II ONLY)

8.M6 Flange Nuts, (2)

9.M6 x 12 Hex Bolts, (2)

10.#8 x 1/2” Sheet metal screw, (4)

Tools Required

1/4” socket driver

10 mm socket driver or wrench

OR, IN THE ABSENCE OF LOCAL

CODES, WITH THE CURRENT ANSI/

NFPA 70, NATIONAL ELECTRICAL

CODE OR CSA C22.1-CANADIAN

ELECTRICAL CODE.

„ THIS UNIT IS SUPPLIED WITH A

THREE-PRONG (GROUNDING) PLUG

FOR PROTECTION AGAINST SHOCK

HAZARD AND SHOULD BE PLUGGED

DIRECTLY INTO A PROPERLY

GROUNDED THREE-PRONG

RECEPTACLE. DO NOT CUT OR

REMOVE THE GROUNDING PRONG

FROM THE PLUG.

„ ALWAYS DISCONNECT THE POWER

SUPPLY WHEN PERFORMING ANY SERVICE ON THE FIREPLACE INSERT.

 

 

 

 

10

 

 

 

 

7

Upper Holes

 

 

 

 

for GF100

 

 

 

 

DV II

 

 

 

 

Lower Holes

4

6

 

 

 

 

 

for GF200

 

 

 

 

DV II

 

 

 

10

 

 

 

 

10

 

 

 

 

 

 

2

1

9

 

 

 

 

53 8

Figure 35. Blower Kit Components

Installation

1.Unpack and check the con- tents of the blower kit. Con- tact your dealer if any damage is evident or parts are missing. See fig. 35.

2.Attach the Control Box to the Snapstat Bracket using two #8 x 1/2” sheet metal screws. As shown in fig. 35, use the pair of mounting holes appro- priate for your stove.

3.Attach the Control Box to the studs located underneath the stove in the middle of the firebox floor using the two M6 hex nuts and a 10 mm socket driver or wrench. See fig. 36.

MANUAL

Snapstat

OFF

AUTO

BLOWER

Secure with

two Hex Head

Flange Nuts

Figure 36. Attach Control Switch Box.

24