GF 100 DV II Nordic QT
GF 200 DV II Lillehammer
Jøtul GF 100 DV II Nordic QT Specifications
Input Rates
Natural Gas
17,000 BTU/hr. maximum input
9,900 BTU/hr. minimum input
Propane
16,000 BTU/hr. maximum input
8,700 BTU/hr. minimum input
Inlet Pressure: | MIN | MAX | |
Natural Gas: | 5.0 WC (1.24 kPa) | 7.0 WC (1.74 kPa) | |
Propane: | 12.0 WC (2.98 kPa) | 14.6 WC (3.63 kPa) | |
Manifold Pressure: | MIN | MAX | |
Natural Gas: | 1.2 WC (0.29 kPa) | 3.8 WC (0.94 kPa) | |
Propane: | 2.9 WC (0.72 kPa) | 11.0 WC (2.74 kPa) |
Piezo Ignitor / Standing Pilot
Weight: 150 lbs.
The Jøtul GF 100 DV II Nordic QT is a Direct Vent gas heater designed as a sealed combustion, air circulating gas appliance for residential applications. This appliance is approved for installation using
6 5/8" X 4" vent pipe from the following manufacturers: Simpson
Security Vent, Ltd. Amerivent Inc. Selkirk Metalbestos
The Jøtul GF 100 DV II Nordic QT gas stove is designed to burn NATURAL GAS or PROPANE only. It is shipped from the factory equipped to burn Natural Gas. If use with Propane is desired, the stove must first be converted for use with that gas. Use the LP Fuel Conversion Kit 155628 included with this stove See page 14 for instructions.
20 5/8”
524 mm
22 1/4”
565 mm
18 1/4” | 16 3/4 ” | |
464 | ||
425 mm | ||
mm | ||
|
Flue Collar
Centerline
16 3/4”
425 mm
Leg To
Leg
14”
356 mm
GF 100 DV II Miscellaneous Kit Contents
• Fuel Conversion Kit - LP | 155628 |
•Rear Air Intake Restrictor Plate, Black
• | Side Air Intake Restrictor Plates, (2) .... | 22099192 |
| or Jøtul Iron - 22099185 | |
* | Decorative Wall Shield, Black | 22092692 |
| or Jøtul Iron | 22092692 |
GF 100 DV II Accessories |
| |
• | Blower Kit | 155631 |
• | Antique Brick Kit | 155815 |
• | Fuel Conversion Kit - NG | 155629 |
• | Wall Thermostat | 750003 |
• | Remote Control | 129706 |
• Mobile Home Floor Bracket Kit | 154342 |