GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

Jøtul GF 100 DV II Nordic QT Specifications

Input Rates

Natural Gas

17,000 BTU/hr. maximum input

9,900 BTU/hr. minimum input

Propane

16,000 BTU/hr. maximum input

8,700 BTU/hr. minimum input

Inlet Pressure:

MIN

MAX

Natural Gas:

5.0 WC (1.24 kPa)

7.0 WC (1.74 kPa)

Propane:

12.0 WC (2.98 kPa)

14.6 WC (3.63 kPa)

Manifold Pressure:

MIN

MAX

Natural Gas:

1.2 WC (0.29 kPa)

3.8 WC (0.94 kPa)

Propane:

2.9 WC (0.72 kPa)

11.0 WC (2.74 kPa)

Piezo Ignitor / Standing Pilot

Weight: 150 lbs.

The Jøtul GF 100 DV II Nordic QT is a Direct Vent gas heater designed as a sealed combustion, air circulating gas appliance for residential applications. This appliance is approved for installation using

6 5/8" X 4" vent pipe from the following manufacturers: Simpson Dura-Vent GS

Security Vent, Ltd. Amerivent Inc. Selkirk Metalbestos

The Jøtul GF 100 DV II Nordic QT gas stove is designed to burn NATURAL GAS or PROPANE only. It is shipped from the factory equipped to burn Natural Gas. If use with Propane is desired, the stove must first be converted for use with that gas. Use the LP Fuel Conversion Kit 155628 included with this stove See page 14 for instructions.

20 5/8”

524 mm

22 1/4”

565 mm

18 1/4”

16 3/4 ”

464

425 mm

mm

 

Flue Collar

Centerline

16 3/4”

425 mm

Leg To

Leg

14”

356 mm

GF 100 DV II Miscellaneous Kit Contents

• Fuel Conversion Kit - LP

155628

Rear Air Intake Restrictor Plate, Black -22111092 or Jøtul Iron - 22111085

Side Air Intake Restrictor Plates, (2) ....

22099192

 

or Jøtul Iron - 22099185

*

Decorative Wall Shield, Black

22092692

 

or Jøtul Iron

22092692

GF 100 DV II Accessories

 

Blower Kit

155631

Antique Brick Kit

155815

Fuel Conversion Kit - NG

155629

Wall Thermostat

750003

Remote Control

129706

• Mobile Home Floor Bracket Kit

154342

4

Page 4
Image 4
Jotul GF 100 DV II, GF 200 DV II manual Jøtul GF 100 DV II Nordic QT Specifications, Input Rates, GF 100 DV II Accessories