GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

Optional Wall Thermostat or Remote Control

Use only a 750 millivolt DC two-wire circuit thermostat with this appliance. The thermostat should be placed in the same room as the heater, typically 5 feet off the floor. Avoid drafty areas or any area that may affect the accuracy of the thermostat.

The thermostat should be connected to the Nordic QT using a minimum of 16 gauge wire with a maximum length of 35 feet of wire.

Connect the two thermostat wire leads to the two lower terminals on the terminal block located directly to the right of the valve. Do not overtighten the con- nections. IT IS NOT NECESSARY TO DISCONNECT ANY OTHER WIRES. See Fig. 27.

For thermostatic operation, the On/Off/T-Stat switch on the back of the stove must be in the T-stat position, and the pilot light must be running, as it is the power source for the thermostat.

At the thermostat, the two wires should be con- nected to the two connection screws on the thermostat base plate per the manufacturer’s instructions.

Remote Control

When using a remote, the remote receiver should be wired to the terminal block the same way the thermo- stat would be. See the instructions above.

Follow the operating instructions included with the Remote Control unit.

CAUTION:

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER OR DANGEROUS OPERATION. ALWAYS VERIFY PROPER OPERA- TION AFTER SERVICING THE APPLIANCE.

Log Set Installation

NOTE: Install the optional Brick Kit, if appropriate, before installing the Log Set. See page 30.

The Log Set and Ember Stones are packaged in foam inside the firebox. These must be installed in the firebox prior to burner operation. Wear gloves to prevent skin irritation from the ceramic fibers.

Position the Rear Log assembly as shown in fig 28, engaging the pins on the burner skirt with the adjacent holes in the underside of the log.

Locate the Middle Log as shown in fig. 29.

Also included is a bag of ember stones that simulate glowing coals when the burner is operating. These should be spread thinly over the burner plate.

NOTE: Keep the ember stones 1/4” away from the edge of the Burner Skirt. All the embers do not have to be used.

Figure 28. Install Rear Log.

THERMOPILE

TH

TP

TH

TP

VALVE

TERMINAL

BLOCK

Figure 27. Accessory wiring diagram.

ROCKER

SWITCH

ON

OFF

STAT

OPTIONAL

THERMOSTAT

or

REMOTE

CONTROL

Pilot

 

Assembly

 

1/4”

1/4”

6 mm

6 mm

Figure 29. Middle Log and ember stones in place.

20

Page 20
Image 20
Jotul GF 100 DV II, GF 200 DV II manual Optional Wall Thermostat or Remote Control, Log Set Installation