Jotul GF 400 DV manual Masonry or Prefabricated Chimney Conversion, Important Notice

Models: GF 400 DV

1 32
Download 32 pages 8.44 Kb
Page 13
Image 13
Masonry or Prefabricated Chimney Conversion

Masonry or Prefabricated Chimney Conversion

The GF 400 DV Sebago is approved for use with listed chimney conversion kits from any of the manufacturers listed on page 8. These kits are for use in a masonry chimney or a prefabricated solid fuel listed chimney. See

 

Exhaust

Vertical

 

Termination

 

Gas

 

Cap

 

 

Cap Adaptor-

 

 

included in

 

Intake Air

#934 Kit

 

 

 

fig. 15.

These installation requirements must be followed:

1.Use the guidelines for Coaxial Vent Termination appropriate for your gas type on pages 11 - 12.

2.In masonry chimney, a fireclay liner or listed steel liner, must be present the entire length of the chim- ney.

3.Chimney height should not exceed 35 ft. (10.66 m).

4.The liner must have an inside dimension of 6” round or greater.

5.Prefabricated chimneys must be UL 103 or ULC S-629 listed and have a minimum INSIDE diameter of 6 inches, (150 mm). Prefabricated chimneys must be listed for the specific Chimney Conversion Kit you choose.

4” Flex Pipe not included in kit

Support/Wall Thimble Cover

Use standard vent pipe from stove to thimble from the same manufacturer

IMPORTANT NOTICE

THE USE OF AN EXISTING CHIMNEY AS AN AIR INTAKE IS NOT COVERED UNDER THE ANSI Z21.88-1999-CSA 2.33-M99 TEST METHODS AND RE-

SULTING ITS/WHI PRODUCT CERTIFI- CATION. THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD.

Figure 15. Vent System through a masonry chimney using a chimney conversion kit. May also be used in listed prefabricated chimneys. Drawing is for illustrative purposes only - DO NOT VENT TWO APPLIANCES INTO A SINGLE CHIMNEY.