General Information

„THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.

„The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.

„This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passage- ways of the appliance be kept clean.

„THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE.

„The installation must conform to local codes. Your local Jøtul dealer can assist you in determining what is required in your area for a safe and legal installa- tion. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector, or authority having jurisdiction, to determine what regulations apply in your area.

„CODE COMPLIANCE : Your local officials have final authority in determining if a proposed installation is acceptable. Any requirement that is requested by the local authority having jurisdiction, that is not specifically addressed in this manual, defaults to local code. In the absence of local codes, the installa- tion requirements must comply with the current National codes. In the U.S., these requirements are established in the National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code.

„Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149.

„DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER. Call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which may have been under water.

„Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.

Glass Panel

Do not operate this appliance with the glass front removed, cracked, or broken. Replacement of the glass should be done by a licensed or qualified service person. Only remove glass for routine service. Always handle glass carefully.

Unpacking your stove

1.Remove the Top Plate of the stove by simply lifting it straight off of the stove body.

2.To open the firebox, disengage the two Glass Frame Latches located on top of the firebox. Pull each handle forward to clear the latch from the notch in the frame.

Glass Frame

Latch

3.Familiarize yourself with the installation require- ments specified in this manual, before beginning the installation.

Hardware Bag Contents

Fuel Conversion Kit - LP................................ 155351

Ember Bag , 4 oz. ............................................ 129123

THIS FIREPLACE IS SHIPPED FROM THE FACTORY FOR USE WITH NATURAL GAS ONLY. IF USE WITH PROPANE IS DESIRED, THE APPLIANCE MUST FIRST BE CONVERTED USING THE FUEL CONVERSION KIT PROVIDED, #155351. CONVERSION SHOULD BE MADE BEFORE THE APPLIANCE IS INSTALLED. SEE PG. 16.

5

Page 5
Image 5
Jotul GF 400 DV manual Unpacking your stove, Glass Panel, Hardware Bag Contents

GF 400 DV specifications

The Jotul GF 400 DV is a highly sought-after gas stove, known for its excellent efficiency and stylish design. This innovative heating solution combines traditional aesthetics with modern technology to create a product that is not only functional but also enhances any living space.

One of the standout features of the Jotul GF 400 DV is its elegant cast iron construction. The durability of cast iron ensures that the stove retains heat longer, providing warmth even after the fire goes out. The design incorporates a large viewing window that allows for an unparalleled view of the flames, fostering a cozy atmosphere. The stove is available in several finishes, including classic black, which complements a variety of home decors.

Efficiency is a key characteristic of the GF 400 DV, as it is designed to achieve a high thermal efficiency rating. It utilizes direct venting technology, allowing for easy installation and efficient combustion. This technology facilitates the venting of exhaust gases outside the home, ensuring indoor air quality remains pristine. The adjustable heat output allows users to customize the warmth according to their needs.

Another impressive feature of the Jotul GF 400 DV is the inclusion of a variable flame adjustment system. This system enables users to control the intensity of the flames, providing both ambiance and practicality. The stove can produce up to 25,000 BTUs, making it suitable for heating medium to large spaces, with an estimated heating area of around 800 to 1,500 square feet.

The GF 400 DV is equipped with electronic ignition for hassle-free startup. Additionally, it features a remote control option, allowing users to operate the stove conveniently from a distance. The manual control option is also available for those who prefer a more traditional experience.

In terms of safety, the stove comes with built-in safety measures, including a flame failure device that automatically shuts off the gas supply if the flame goes out unexpectedly.

Overall, the Jotul GF 400 DV gas stove represents the perfect blend of traditional craftsmanship and modern efficiency. Its combination of aesthetics, innovative features, and practical heating capabilities makes it an ideal choice for homeowners looking to add warmth and character to their living spaces. Whether you’re enjoying a quiet evening at home or entertaining guests, this stove is sure to impress with its performance and beauty.