Jotul GF 400 DV Stove and Vent Clearance Requirements, Alcove Installation, Corner Clearances

Models: GF 400 DV

1 32
Download 32 pages 8.44 Kb
Page 7
Image 7
Stove and Vent Clearance Requirements
See figs. 2-4.

Stove and Vent Clearance Requirements

Minimum Clearances from the Stove to Combustibles:

Rear:

2” (51 mm)

Ceiling:

32 1/4” (819 mm)

Corner:

2”

(51 mm)

Sides:

3”

(76 mm)

Minimum Clearances from the Vent Pipe to Combustibles:

Horizontal Run:

 

 

Off the top of the pipe 2”

(51 mm)

Off the sides and bottom 1”

(25 mm)

Vertical Run:

 

 

All sides

1” (25 mm)

Minimum Ceiling or Alcove Height

 

 

 

 

Max. Mantel Depth

 

 

 

 

 

12.5”

 

 

 

 

 

10.25”

 

 

 

 

 

 

8”

 

 

 

 

 

 

5.75”

 

 

 

 

 

Min. Mantel Depth

3.5”

 

61” 155 cm

 

 

 

Max. Top Trim Depth = 1”

 

 

43 3/4” 111 cm

 

2”

(5.1cm)

 

 

 

 

1/2” 118cm

 

5/8” 108.3cm

 

 

46

45 1/8” 114.6 cm

42

40 1/4” 102.2 cm

28 1/2” 72.3 cm

Figure 2. Mantel and Trim Clearance specifications. Back of bottom plate is flush with the fireplace face. Subtract 2 1/4” with Short Legs.

2”

(51 mm)

To Rear Wall

3”

3”

(76 mm)

(76 mm)

Figure 3. Parallel Installation Clearances.

2”

51 mm

2”

51 mm

Figure 4. Corner Clearances.

Alcove Installation

Maximum Alcove Depth: 24” (61 cm)

Minimum Alcove Width: 31 3/4” (80.6 cm)

Minimum Ceiling Height: 61” (155 cm)

With Short Legs (6”) :

59” (150 cm)

Alcove dimensions result from test configurations, not stove clearance specifications.

7

Page 7
Image 7
Jotul GF 400 DV manual Stove and Vent Clearance Requirements, Alcove Installation, Parallel Installation Clearances